3 Transport/Temporary Storage/Disposal
12 of 40
KSB Delta Solo Compact
1983.848/01-EN
3 Transport/Temporary Storage/Disposal
3.1 Checking the condition upon delivery
1. On transfer of goods, check each packaging unit for damage.
2. In the event of in-transit damage, assess the exact damage, document it and
notify KSB or the supplying dealer and the insurer about the damage in writing
immediately.
3.2 Transport
DANGER
Pressure booster system tipping over
Danger to life from falling pressure booster system!
▷
Never suspend the pressure booster system by its power cable.
▷
Do not lift the pressure booster system by its manifold.
▷
Observe the applicable local accident prevention regulations.
▷
Observe the information on weights, centre of gravity and fastening points.
▷
Use suitable and permitted transport equipment, e.g. crane, forklift or pallet
jack.
ü
Transport equipment / lifting equipment suitable for the corresponding weight
has been selected and is on hand.
1. Remove the packaging. Remove the caps from the connection openings.
2. Check for any in-transit damage.
3. Transport the pressure booster system to the place of installation.
4. Detach the pressure booster system from the pallet using a suitable tool.
5. Attach the pressure booster system to the lifting equipment as illustrated.
6. Lift it off the wooden skids. Dispose of the wooden skids.
7. Carefully place down the pressure booster system at the site of installation.
3.3 Storage/preservation
CAUTION
Damage during storage due to frost, moisture, dirt, UV radiation or vermin
Corrosion/contamination of pressure booster system!
▷
Store the pressure booster system in a frost-proof room. Do not store outdoors.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage of the pressure booster system!
▷
Only open the openings of the pressure booster system at the time of
installation.
NOTE
Rotate the shaft by hand every three months, e.g. via the motor fan.
If commissioning is to take place some time after delivery, the following measures
are recommended when storing the pressure booster system: