9 Trouble-shooting
46 of 52
Calio S
1157.8117/01-EN
9 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB service is required.
A
Pump is running, but does not deliver
B
Pump does not start up or pump running irregularly
C
Pump running but not delivering water.
D
Noises during pump operation
Table 21:
Trouble-shooting
Error value
Possible cause
Remedy
5)
A
▪
▪
Spanner symbol shown on display /
Service mode activated
▪
Reset the control system. Check the power supply and fuses.
▪
Disconnect the plug (power cable) or press control buttons
(+) and (-) simultaneously for 5 seconds until the spanner
symbol disappears from the display (Service mode
deactivated).
B
▪
Impurities in the pump
▪
B
▪
Blockage in the pump
▪
C
▪
Air in the system
▪
Shut-off elements closed
▪
Vent the system and the pump. (
▪
Open the shut-off elements.
D
▪
Power too high
▪
System pressure too low
▪
Air in the system
▪
Pump running dry
▪
Reduce the discharge head setpoint.
▪
Increase the system pressure by filling more water into the
boiler.
▪
Vent the system and the pump. (
▪
5
Release pump set pressure before attempting to remedy faults on parts which are subjected to pressure.
Summary of Contents for Calio S