5 Installation at Site
23 of 52
Calio S
1157.8117/01-EN
5.6.1 Connecting the power cable
Table 7:
Power cable dimensions
Power cable dimensions
Values
Outside diameter
5,5 - 8,0 mm
Cross-section
0,75 - 1,5 mm
2
(solid or stranded
3)
)
1. Verify the power supply at the site against the data on the name plate.
2. Switch off the power supply and make sure it cannot be switched on again
unintentionally.
3. Fit the union nut and joint ring on the power cable.
4. Guide the power cable through the plug housing until the cable ends are freely
accessible.
5. Strip the power cable as shown in the respective illustration.
Strip about 18 mm of the earth conductor sheath. Strip about 13 mm of the
neutral conductor sheath and L conductor sheath.
Strip 6 mm of each core's sheath as a minimum.
18
13
6
Fig. 4:
Stripping the power cable [mm]
6. Connect the cores at the contact insert.
Fig. 5:
Connecting the cores at the contact insert
L
Conductor / phase (230 V)
N
Neutral conductor
Earth conductor
7. Select straight or angled plug housing (scope of supply) according to the
installation position. If the electronic system housing (control panel) is turned by
90 degrees, only use the straight plug housing (see illustration).
3
Fit wire end sleeves on stranded/flexible electric cables.
Summary of Contents for Calio S
Page 1: ...High efficiency Circulator Pump Calio S Installation Operating Manual...
Page 50: ......