5 Installation at Site
22 of 62
Calio Pro / Calio Pro Z
1157.820/01-EN
Permissible installation positions
Fig. 5:
Permissible installation positions (single pump)
Fig. 6:
Permissible installation positions (twin pump)
Turning the electronic system housing (optional)
The electronic system housing with integrated control unit can be turned. The display
must always be in a readable position. Positioning must be effected with the pump
set removed from the system.
1
Fig. 7:
Turning the electronic system housing
1. Undo four hexagon socket head cap screws (1) between the motor housing and
pump casing and store them.
2. Turn the electronic system housing until it has reached the required position.
Compare it against the permissible installation positions. Adjust the position if
required.
3. Tighten four hexagon socket head cap screws (1) with a suitable tool.
Tightening torque = 9 Nm