5 Installation at Site
27 of 84
Amarex N
2563.84/08-EN
Table 12:
Guide wire tension
Size
Tightening torque
Guide wire tension
M
A
[Nm]
P [N]
50 - ...
9
6000
65 - ...
9
6000
80 - ...
14
6000
100 - ...
14
6000
150 - ...
14
6000
5.3.1.4 Fitting the guide rail arrangement (1 or 2 guide rails)
The pump set is guided into the sump or tank along one or two vertical guide rails. It
attaches itself automatically to the duckfoot bend which has been fitted to the floor.
NOTE
The guide rails are not included in KSB's scope of supply.
Select guide rail materials which are suitable for the fluid handled or as specified by
the operator.
Table 13:
Guide rail dimensions
Hydraulic system
size
Outside diameter
Wall thickness [mm]
6)
[mm]
Minimum
Maximum
DN 50
33,7
2
5
DN 65
33,7
2
5
DN 80
60,3
2
5
DN 100
60,3
2
5
Fitting the mounting bracket
90-3.37
894
Fig. 9:
Fitting the mounting bracket
1. Fasten mounting bracket 894 to the edge of the sump opening with steel
anchor bolts 90-3.37 and tighten the anchor bolts to a tightening torque of
10 Nm.
Observe the hole pattern for the anchor bolts. (See outline drawing.)
6)
To DIN 2440/2442/2462 or equivalent standards
Summary of Contents for Amarex N series