5 Installation at Site
25 of 84
Amarex N
2563.84/08-EN
F
x
F
z
F
y
M
y
M
z
M
x
Fig. 6:
Permissible flange loads
Table 11:
Permissible flange loads
Nominal flange
diameter
Forces
[N]
Moments
[Nm]
F
y
F
z
F
x
∑F
M
y
M
z
M
x
∑M
50
1350
1650
1500
2600
1000
1150
1400
2050
65
1700
2100
1850
3300
1100
1200
1500
2200
80
2050
2500
2250
3950
1150
1300
1600
2350
100
2700
3350
3000
5250
1250
1450
1750
2600
150
4050
5000
4500
7850
1750
2050
2500
3650
5.3.1.3 Fitting the guide wire arrangement
The pump set is guided into the sump or tank along two parallel, tightly stretched
guide wires made of stainless steel. It attaches itself automatically to the duckfoot
bend which has been fitted to the floor.
NOTE
Should site conditions/piping layout, etc. require the wire to run off the vertical, do
not exceed a maximum angle of 5° to ensure reliable fitting and guiding of the
pump set.