7.5.2 Reassembling the motor section
DANGER
Wrong screws/bolts
Explosion hazard!
▷
Only use original screws/bolts on explosion-proof submersible mixers.
NOTE
Before reassembling the motor section, check that all joints relevant to explosion
protection (flamepaths) are undamaged. Components with damaged flamepaths must be
replaced. Only use original spare parts made by KSB for explosion-proof submersible
mixers. The flamepaths are shown in the relevant drawings. (⇨ Section 9.2 Page 48)
All screwed connections closing off the flameproof enclosure must be secured with a
thread-locking agent (Loctite Type 243).
7.5.3 Installing the mechanical seal
The following rules must be observed when installing the mechanical seal:
▪
Work cleanly and accurately.
▪
Only remove the protective wrapping of the contact faces immediately before
installation takes place.
▪
Prevent any damage to the sealing surfaces or O-rings.
932.04
932.03
471
433.01
433.02
932.05
Fig. 15: Installing the mechanical seal
✓
The individual parts are kept in a clean and level assembly area.
✓
All disassembled parts have been cleaned and checked for wear.
✓
Any damaged or worn parts have been replaced by original spare parts.
✓
The sealing surfaces have been cleaned.
1. Clean the shaft, and touch up any score marks or scratches with a polishing cloth,
if necessary. If score marks or scratches are still visible, fit a new gear unit and
shaft.
2. Fit mechanical seal 433.01.
3. Fit circlip 932.04.
4. Insert seal cover 471.
5. Fit circlip 932.03.
6. Fit mechanical seal 433.02.
7. Fit circlip 932.05.
Installing the mechanical
seal
7 Servicing/Maintenance
40 of 60
Amaprop®
Goodnal STP ST041 Biological Treatment (KSB Amaprop Installation and Operating Manual) Vendor Manual
Q-Pulse Id VM386
Active 29/10/2013
Page 40 of 60