5.2.3 Checking the lubricant level
903.01
411.01
Lubricant filler plug
on gear unit
Lubricant check plug
on gear unit
Fig. 4: Checking the lubricant (propeller not shown)
The lubricant reservoirs are filled with an environmentally-friendly, non-toxic
lubricant at the factory.
1. Position the submersible mixer as shown.
2. Undo screw plug 903.01 and joint ring 411.01.
⇨
The lubricant level must reach the filler opening.
3. If the lubricant level is lower, top up lubricant through the filler opening until
the lubricant reservoir overflows.
4. Fit screw plug 903.01 and joint ring 411.01 again.
1. Unscrew the lubricant check plug on the gear unit.
⇨
The lubricant level must reach the filler opening.
2. If the lubricant level is lower, unscrew the lubricant filler plug on the gear unit
and top up lubricant through the filler opening until the lubricant flows out of
the lubricant check opening.
Checking lubricant level of
mechanical seal
Checking lubricant level of
gear unit
5 Installation at Site
Amaprop®
17 of 60
Goodnal STP ST041 Biological Treatment (KSB Amaprop Installation and Operating Manual) Vendor Manual
Q-Pulse Id VM386
Active 29/10/2013