5 Installation at Site
15 of 32
Ama-Drainer N 301/302/303/358
5.3 Fitting the swing check valve and socket (if supplied but not fitted)
Ama-Drainer N 301/302/303
Ama-Drainer N 358
1
3
4
5
2
6
1
Fig. 3:
Fitting the swing check valve and socket
1
Discharge nozzle
2
Socket 1 1/4"
3
Swing check valve
4
Hose connection 1 1/2"
5
Suction valve
6
Screw plug
1.
Position the swing check valve on the discharge nozzle.
For Ama-Drainer N 301/302/303: Make sure the disc of the swing check valve
opens upwards.
For Ama-Drainer N 358: Make sure the disc of the swing check valve opens
downwards.
2.
Screw the socket on with the long thread and tighten it.
5.4 Adjusting the cut-in level control
Fig. 4:
Switching levels
b
Cut-out level
c
Cut-in level
Table 4:
Cut-in levels and cut-out levels
Type series
Factory setting
Limits
2)
Cut-out level b
3)
[mm]
Cut-in level c
3)
[mm]
Cut-out level b
[mm]
Cut-in level c
3)
[mm]
Ama-Drainer N 301 SE
70
145
295
375
Ama-Drainer N 302 SE
110
200
315
420
Ama-Drainer N 303 SE
110
200
315
420
Ama-Drainer N 358 SE
110
230
395
540
For manual operation value b must not be lower than the following values:
▪
Ama-Drainer N 301/302/303: 15 mm
▪
Ama-Drainer N 358: 37 mm
2)
Maximum values
3)
Minimum values for automatic operation
Summary of Contents for Ama-Drainer N 301