5 Installation at Site
14 of 32
Ama-Drainer N 301/302/303/358
5 Installation at Site
5.1 Safety regulations
DANGER
Unsuitable electrical installation
Danger to life!
▷
Make sure the electrical installation meets the VDE 0100 installation rules (i.e.
sockets with earthing terminals).
▷
Make sure the electric mains is equipped with a residual current device of
maximum 30 mA.
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Only use the plugs and power cables supplied with the pump.
DANGER
Use in an outdoor area
Danger of death from electric shock!
▷
Any extension cords must match the quality of the supplied pump cable (10-
metre cable length).
▷
Do not expose electrical connections to any moisture.
DANGER
Continuous pump operation in swimming pools, garden ponds or similar
Danger of death from electric shock!
▷
Make sure that nobody is in the water while the pump is in operation.
▷
Only use the pump for draining swimming pools, garden ponds, etc. (It is
impermissible to use this pump as a recirculation pump, for example.)
5.2 Checks to be carried out prior to installation
Before installing the pump make sure that the following requirements are met:
▪
Check the data on the name plate of the pump to make sure it can be operated
on the available mains.
▪
The fluid to be handled matches the description of suitable fluids.
▪
The above safety instructions have been complied with.