5 Installation at Site
17 of 32
Ama-Drainer N 301/302/303/358
Ama-Drainer N 358
1.
Screw on the G 1 ½" adaptor for a hose of 40 millimetres inner diameter (an
elbow is available as an option).
2.
Fasten the hose with a hose clip.
5.6 Installing the pump set
c
b
E
h
Fig. 6:
Installation dimensions and switching levels
c
Cut-in level
b
Cut-out level
Table 5:
Recommended installation dimensions
Size
E
[mm]
h
[mm]
301
400×400
400
302/ 303
400×400
500
358 SE
400×450
550
1.
If required, suspend the pump set using a rope attached to the handle.
2.
Place the pump set on a solid surface.
Observe the recommended installation dimensions.
3.
Position the pump set so that the float can move freely.
5.7 Connection to power supply
Plug the pump into the mains socket.
The pump switches on and off automatically.