KRUSMAN 7023 Instructions For Installation, Use And Maintenance Manual Download Page 8

 

Filling 

The water inlet is located on top of the trailer (see below). We recommend connecting the trailer to a 
water supply using a pipe with a nominal diameter of 1½". Water pressure should have a value of no 
more than 6,5 bar. As high pressure may damage the structure of the tank).  
 
The Krusman 7023 portable emergency tank shower and eye wash must be securely positioned on a 
flat level surface and using the trailer brake and both the front and rear support stand. Ensure the 
complete unit is stable and the shower and eye/face wash is within the relevant standards. This must 
be determined at the installation site by installation personnel in accordance with local conditions. 

 

 

 

                                             (Filling point and enterance for maintenance) 

Initial Start-up 

After the installation the shower has to be checked for its function. If the unit does not function see 
Malfunction/trouble shooting section of manual.   
 

 

                (Power cord included) 
 

The pump installed on the Krusman 7023 is the Lowara SC407C (see handbook delivered with unit). 
When the red light is turned on at the control panel that indicates the pump is working (see below).

 

 

  

 

         

(Installed pump)                                    (Pump in use) 

  

 

 

 

Summary of Contents for 7023

Page 1: ...Maintenance KRUSMAN Portable Tank Shower Systems EN 15154 3 2009 EN 15154 4 2009 and ANSI Norm Z358 1 2009 Product displayed is for illustration purposes only and may differ slightly Series Portable...

Page 2: ...mensions of the trailer 5 Installation 6 Requirements for the Installation Site 6 Proximity Switch connection 7 Filling 8 Initial Start up 8 Use 9 Body Showers with pull rod 9 Models with Optional Eye...

Page 3: ...m non observance of the instructions for use and maintenance or from non observance of the specified conditions of use Only products which are free of defects and which demonstrate the characteristics...

Page 4: ...hat the user has direct access to the shower Safety Precautions for Use Maintenance Inspection and Installation Work The operating company must assure that all maintenance and installation work is exe...

Page 5: ...ow Alternatively ensure that the bowser and pump are located in a frost free environment even when the trailer is fitted with a submersible heating element THE TRAILER CANNOT BE LEFT OUTSIDE IN FROSTY...

Page 6: ...potential danger and can be accessed within 10 seconds A distance of 3 to 6 metres is recommended in the case of highly caustic substances The area around the shower should be well illuminated and the...

Page 7: ...h when activated will ensure there is water follow at either the eye wash and or Emergency shower when connected correctly Ensure the two connectors pictured below are connected correctly prior to sta...

Page 8: ...Ensure the complete unit is stable and the shower and eye face wash is within the relevant standards This must be determined at the installation site by installation personnel in accordance with local...

Page 9: ...s installed it has been connected by a licensed electrician and is functioning correctly when the unit has left our warehouse In this connection the safety instructions have been followed A maximum wa...

Page 10: ...er inserts be replaced see below replacement of eye wash filters replacement of eye wash filters Semi Annual Inspection Maintenance and inspection executed by KRUSMAN or a commissioned certified perso...

Page 11: ...The shower system can be completely dismantled The individual materials i e metal plastic electrical components etc can be separated and disposed of at a recycling centre National and local disposal r...

Page 12: ...12 Letter of conformity...

Reviews: