8
Filling
The water inlet is located on top of the trailer (see below). We recommend connecting the trailer to a
water supply using a pipe with a nominal diameter of 1½". Water pressure should have a value of no
more than 6,5 bar. As high pressure may damage the structure of the tank).
The Krusman 7023 portable emergency tank shower and eye wash must be securely positioned on a
flat level surface and using the trailer brake and both the front and rear support stand. Ensure the
complete unit is stable and the shower and eye/face wash is within the relevant standards. This must
be determined at the installation site by installation personnel in accordance with local conditions.
(Filling point and enterance for maintenance)
Initial Start-up
After the installation the shower has to be checked for its function. If the unit does not function see
Malfunction/trouble shooting section of manual.
(Power cord included)
The pump installed on the Krusman 7023 is the Lowara SC407C (see handbook delivered with unit).
When the red light is turned on at the control panel that indicates the pump is working (see below).
(Installed pump) (Pump in use)