Requirements for the Installation Site
Subfloors must be level, and must be capable of withstanding the weight of the safety showers after
installation and falling. Disconnect the trailer from the towing vehicle (if attached).
Beyond this, the installation site must be arranged such that the safety shower:
Cannot be damaged by vehicles
Allows for unobstructed access by users at all times
Is located less than 30 metres from areas of potential danger and can be accessed within 10
seconds. A distance of 3 to 6 metres is recommended in the case of highly caustic
substances.
The area around the shower should be well illuminated, and the shower itself should be
identified with highly visible signs.
Do not position the unit near dangerous hazards (ie Electricity).
(trailer brake)
(Rear support stand) (Power pannel/ inlet power/circuit board)
(Power cord included)
Note: The Krusman 7023 has been installed with cut off switches which have been preset prior to
shipment which will prevent the heating element and or the pump from working when there is an
insufficient amount of water available.