5
Neglecting to provide personnel with required instruction for proper use of the safety
shower system, which must be held at least once a year
Range of Applications
KRUSMAN safety shower systems are intended for rinsing and decontaminating persons.
Storage and Transport
COLD WEATHER PROTECTION
When the is frost or freezing temperatures and the tank is not used ie, night time, weekends,
holidays etc.. the power supply should be disconnected and the unit should be placed in an area
which is not cold or subject to freezing. We recommend that the tank is emptied (see location of the
plug below.
Alternatively ensure that the bowser and pump are located in a frost free environment even when
the trailer is fitted with a submersible heating element. THE TRAILER CANNOT BE LEFT OUTSIDE IN
FROSTY OR FREEZING CONDITIONS FOR A PERIOD LONGER THAN 10 HOURS.
Note: Improper handling results in increased danger of tipping and the product not functioning!
Dismantle Emergency shower and eye/face wash (return to mounts on top of the trailer, see images
below), all proximity switches and disconnect the power supply before moving to another location.
Failure to do so may damage the unit and cause failures.
(Eye wash mounted)
(Shower attached to tank)
(Drainage point)
Dimensions of the trailer
Volume: 1200L
Length: 9' 2" (2795mm)
Width: 5' 1" (1549mm)
Height: 4' 2" (1270mm)
Gross Weight: 264Kg, Unfilled 1500Kg Gross