12
• To do this, dismantle the nozzle as instructed
in the paragraph «Maintenance» and soak
the scaled parts for 5 minutes in 1/3 of the
mixture obtained during the first run-
through. Rinse the various parts thoroughly
before replacing them.
Problems, likely causes and
corrective actions
Problems
Probable
Corrective
causes
actions
Espresso not
The accessories
Pre-heat the
hot enough.
are cold
accessories
(cups, filter
See the paragraph
and filter holder).
«Preparing an
espresso».
The appliance is
Wait for the
not hot enough.
indicator light
(c) to come on.
Leaking coffee
The filter holder
See paragraph
around the filter
is not fitted
«Preparing an
holder
correctly.
espresso».
There is residual
Clean around
coffee on the edge
the filter and the
of the filter.
seal.
The seal of the
Clean the seal
percolation head
with a damp
is dirty.
cloth.
The seal of the
Contact an
percolation head is
approved KRUPS
defective.
service center.
Very loud noise
No water in the
Fill the tank.
pump.
coming from the
tank.
Tank incorrectly
Press firmly on
fitted.
the tank
Ground coffee too
Use freshly
old or dry.
ground coffee.
Water does not
No water in the
Fill the
flow properly.
tank.
tank.
Tank badly
Press firmly on
fitted.
the tank.
Water does not
The filter is
Clean the filter
flow properly.
blocked-the
and the grid of
ground coffee is
the percolation
too fine or
head. See the
compacted
paragraph
too tightly.
«Maintenance »
and try using a
coarser ground
coffee.
Grid of the
Put the grid to
percolation head
soak in the
is clogged.
descaling
solution. See the
paragraph
«Descaling».
Appliance scaled.
See the Paragraph
«Descaling».
Water passes
Ground coffee too
Try a finer
too quickly.
coarse.
ground coffee.
Insufficient quan-
Use the spoon
ty of ground
supplied to
coffee.
measure out the
coffee.
Ground coffee not
Compact the
compacted.
ground coffee
more.
The espresso has
Ground coffee
Try using a finer
no head (crema
too coarse.
ground coffee.
on the coffee)
Ground coffee not
Compact the
compacted
ground coffee
enough.
more.
Ground coffee old
Use a fresh
or too dry.
ground coffee.
Insufficient
Steam /cappuccino
See paragraph
foam on milk.
nozzle blocked
«Maintenance».
Milk too old.
Use fresh milk
Milk is lukewarm.
Cool milk in
the refrigerator.
Residual water
Ground coffee not
Compact the
in the ground
sufficiently compac- ground coffee.
coffee.
ted.
Insufficient
Increase the
quantity
quantity of
of ground coffee.
ground coffee.
There is water
The drip tray
Empty it regularly
around the
is overflowing
appliance.
Summary of Contents for Espremio 01 FNP1
Page 1: ...www krups com lock...
Page 2: ...lock a c b g2 g g1 f k f1 e d h i j h1...
Page 3: ...1 3 5 4 6 2 8 1 2 7 9 10...
Page 4: ...4...
Page 33: ...FNP1 US F E 826 628 A...