Installation
Operating Temperature & Defrosting
SELF-CONTAINED UNITS:
Digital thermostat can be found on the front condensing unit cover. To set to desired temperature, follow the steps below.
1. Press SET for 1 second. The set value will start flashing after a few moments
2. Increase or decrease the value using UP or DOWN
3. Press SET to confirm new value
Manual defrost cycle: Press
DOWN
for more than 3 seconds
The operating temperature for the Self-Contained Back Bar Cooler is preset at the factory for an average of 35°F.
Average operating range is from 29°F to 38°F.
Remote units need to be set by a certified refrigeration technician.
CAUTION:
This temperature is only a set point. If set to 32°F, product will not be 32°F and air temperature inside unit will not be 32°F.
Operating temperature/average temperature is usually 4°F to 5°F above set temperature.
Inspection Upon Receipt
Remove all shipping material from unit before operation.
Please inspect the unit for any hidden freight damage and
report any damage immediately to Krowne Metal Corp.
If included, install optional casters or legs to bottom of
unit. Please avoid turning unit on its side or rear to install
accessories. If this cannot be avoided, unit must be left in
the upright position for 24 hours before operating. All units
come equipped with predetermined mounting holes and self
starting bolts for easy install (bolts are provided only when
casters or legs are ordered from factory). It is important
to check that casters or legs are securely attached with
appropriate mounting hardware.
Electrical Requirements
115 Volt AC, 1 Phase, 60Hz. We recommend using a
dedicated 15 amp circuit minimum. 8’-0” grounded
cord standard on Self Contained Back Bar Coolers, Bottle
Coolers and Mug Frosters. Remote units come with a
terminal block inside the box for a hard wire connection
(supplied by the end user).
At
Krowne Metal Corporation
we are dedicated to customer satisfaction. This installation guide is provided to clarify and
answer any questions you may have regarding our line of Commercial Refrigerators. Please read this guide before attempting
installation or operation. Thank you for choosing Krowne as your refrigeration provider.
Plumbing
Self-Contained Back Bar Coolers have an evaporating pan
and do not require any plumbing hook-up. Remote units
require a drain hook-up. We recommend using 1/2” tubing
and running it through the same knockout used for the
refrigeration hook-up.
Installing of Shelves (Back Bar Coolers)
Shelves and installation clips are shipped within the cooler.
Shelves can be installed based on owner’s preference.
Location
Place unit in desired location and level. It is important for
the unit to be level, or it will not drain properly, and the
doors will not close properly, which in turn will affect the
function of the cooler and void any factory warranty. Allow
2” clearance for Back Bar Coolers in the back. If required,
unit can be sealed to floor using an NSF approved clear
silicone. Excess sealant should be wiped clean.
DO NOT
BLOCK OR OBSTRUCT FRONT GRILL.