background image

KA1000

Dual Alarm Clock with

Wireless Alarm Monitoring Receiver

INSTRUCTION MANUAL

1st Edition

Summary of Contents for KA1000

Page 1: ...KA1000 Dual Alarm Clock with Wireless Alarm Monitoring Receiver INSTRUCTION MANUAL 1st Edition ...

Page 2: ...clock alarms and real time 9 Security timer SCT 10 Select mode test and reading lamp 10 Using LED indicators 11 Battery 11 ACCESSORIES 12 Extended receiver KA1000EX 12 DoorKnock transmitter KA1000DK DoorBell transmitter KA1000DB 13 Telephone ringer transmitter KA1000TR 13 Tactile telephone signaler pager KA1000PG 13 Baby room call signaler KA1000NR 13 Alarm monitor transmitter KA300TX 13 Weather a...

Page 3: ...on unless proper ventilation is provided 14 Unplug the KA1000 from the wall outlet and contact Krown Manufacturer Inc if any of the following conditions occur a When the power cord is damaged or frayed b If liquid has been spilled into the telephone c If the telephone exposed to the rain or water d If the unit does not operate normally when following the user manual adjust only controls that are c...

Page 4: ...ger Equivalent Number of all the devices not exceed five SAVE THESE INSTRUCTIONS Safety Instructions for Batteries Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions 1 Use only with the approved battery pack in your Alarm Clock For base unit 8 4V 170mAh NiMH rechargeable battery GPI International Ltd 17R8H 2 Do not dispose o...

Page 5: ...n of the equipment If this happens the tele phone company will provide advance notice in order for you to make necessary modi fications to maintain uninterrupted service g Should you experience trouble with this equipment please contact Krown Manufacturing Inc 3408 Indale road Fort Worth Texas 76116 Phone number 817 738 2485 For repair or warranty information If the equipment is causing harm to the...

Page 6: ...he display of the clock to ensure there is no confusion It also works with all transmitters from the alarm monitor system made by Krown Mfg You can link all alarm sensors Fire Smoke Carbon mono oxide detectors in your house to be one wireless monitoring system in your bedroom clock It will give you what causes the alarm and help you make a decision of what to do before you leave your bed It helps ...

Page 7: ...ification Bed Shaker Time button Security timer button Alarm 1 button Alarm 2 button AM PM Volume Control Dimmer Test Switch Bed Shaker Strength Lamp ON OFF Switch Power Cord Wall plug External Lamp Plug Sound Shaker Mode Switch Reset button Bed Shaker plug Phone jack Code Dip Switch Door clip or door hanger Doorbell button test button ON OFF Switch ON LED Checklist 1 KA1000 Alarm Clock 2 KA1000DK ...

Page 8: ...attery then replace the battery cover Fig 1 2 2 Set the alarm clock next to a table lamp Turn the table lamp on before plugging into the clock power cord Fig 2 3 3 Plug the bed shaker to the unit and put it under the pillow Fig 2 2 4 Connect the telephone module cord into the unit and plug the other end to tel phone outlet Fig 2 1 5 Plug the power cord to electrical outlet Fig 2 4 B Door Knock Hoo...

Page 9: ...itter at any time repeating those steps Record the description of that transmitter to page 19 of this book for future reference Channel 1 or C1 is used for the Alarm Monitor sensors do not use it for the door knock telephone ringer or Baby room call transmitter of channel 2 or C2 xx Each memory has 3 entries for 3 different kind transmitters If you have more than one transmitter of one kind for ex...

Page 10: ...ll at home you can use the security timer feature Every night the clock KA1000 can turn on the table lamp connected to it for you and turn it off later at 11 pm To pick starting time 1 Press SCT and Hour buttons to change security timer from 6 PM to 7 8 9 10 PM The security timer will automatically turn off at 11 PM to make it look like someone is at home To make people think that a timer was not ...

Page 11: ...lock is working with the battery source Sensor Turns on when it receive of signal from an Alarm Monitor transmitter SCT The SCT LED will turn on when SCT mode is selected Alarm 1 and alarm 2 will be de activated Alarm Turns on when the alarm clock is triggered Battery KA1000 will operate on one 8 4VDC rechargeable battery during a power outage Do not use a regular battery Power is provided for the...

Page 12: ...mitters or erase any unused transmitters if needed To erase a transmitter from memory press and hold test button on the transmitter and light switch of the extended receiver at same time The extended receiver will flash light twice to confirm the transmitter code is erased To clear the whole memory of the extended receiver press and hold the light switch until the LED flashes eight times for clear me...

Page 13: ...elephone outlet and turn on Press the test button on the transmitter If the red LED lights up and the signal received by the clock or extended receiver the system operates perfectly D Tactile telephone ringer pager KA1000PG This product is designed for a deaf blind user The others also enjoy a silent notification from the tactile pager when the telephone rings The package called TRS100 comes with a...

Page 14: ...larm detector triggers the transmitters The channel LED on the KA300RX also turns on to show the activated detector Each LED comes with different colors for easily distin guishing the channel Backup battery and adaptor are included The KA300 kit includes two receivers KA300RX KBS300RX one transmitter KA300TX bed shaker adaptor charger and batteries Purchasing extra transmitters is recommended for ...

Page 15: ...er switch to test The shaker will vibrate for 1 second before it switches to light and sound test Check the switch mode to make sure that you choose shaker and light mode 4 The extended receiver will not flash when the telephone ring The extended receiver needs to recognize the telephone ringer you use in the system Press the telephone ringer transmitter test button and the light switch on the exte...

Page 16: ... is no one at the door or the telephone did not ring Your neighbor may also be using the KA1000 Change the security code on the transmitter and register with the clock again Please read change system security code section page 9 12 How to register a new transmitter to the extended receiver KA1000EX Press and hold the light switch when pressing the test button on the transmitter until the red LED o...

Page 17: ...r KA1000DB 65X40X17 5mm WEIGHT KA1000 0 77Kg Bed shaker 110g Door knock transmitter KA1000DK 45g Doorbell Transmitter KA1000DB 45g OPERATION VOLTAGE KA1000 120VAC Door knock transmitter KA1000DK 3VDC Doorbell Transmitter KA1000DB 3VDC BATTERY KA1000 8 4VDC Rechargeable Door knock transmitter KA1000DK CR2032 Doorbell Transmitter KA1000DB CR2032 Load for AC plug 120VAC 2A Siren 95dB APPROVAL FCC par...

Page 18: ...se include a check or money order make out to Krown Manufacturing in the amount of 15 00 to cover for the Shipping and Handling This warranty does not extend to any Alarm Clock sold by Krown Manufactur ing Inc which has been subjected to misuse neglect accident improper application improper installation or any use in violation of the instruction furnished by Krown Manufacturing Inc This warranty d...

Page 19: ...____________________________________________ ________________ _______________________________________________ ________________ _______________________________________________ ________________ _______________________________________________ ________________ _______________________________________________ ________________ _______________________________________________ ________________ _____________...

Page 20: ...3408 Indale Road Fort Worth TX 76116 Voice 817 738 2485 TTY VP 817 738 8993 Fax 817 738 1970 E Mail Info KrownMfg com Web site www KrownMfg com ...

Reviews: