Summary of Contents for MFC (V Series)

Page 1: ...0 2006 6 6 6 MFC INSTALLATION MANUAL MFC INSTALLATION MANUAL MFC INSTALLATION MANUAL MFC INSTALLATION MANUAL Rev Rev Rev Rev C C C C Issue Issue Issue Issue 2 2 2 2 GENERATION III CAR CONTROL SYSTEMS MFC MFC MFC MFC F F F F V Series V Series V Series V Series INSTALLATION MANUAL ...

Page 2: ...n Harness Connector P1 12 3 4 2 Bluetooth Antenna Connection 12 3 4 3 Serial Data Connector 13 3 4 4 PDA Phone USB Chargers 13 3 4 5 Power And Serial Data LED Indicator 13 3 4 6 Bluetooth LED Indicator 13 4 COMMON INSTALLATION SETUP EXAMPLES WITH THE MFC 14 4 1 Primary Car Control Alarm Style With Remote Start 14 4 2 Control Hydraulics Another Unique Way To Use The MFC 15 4 3 Control Hydraulics An...

Page 3: ... POSSIBLE PC CARPC CONFIGURATIONS 9 Figure 5 MFC CONNECTOR DIAGRAM 10 Figure 6 Main Connector P Detail 12 Figure 7 MFC Example Simple setup 14 Figure 8 Direct MFC Example Setup with Alarm add on 15 Figure 9 MFC Example Setup as Hydraulics Controller 16 Figure 10 Triggered Remote Start 17 Figure 11 Direct Remote Start 18 Figure 12 Ignition Key Positions 20 Figure 13 Connecting MFC to factory door t...

Page 4: ...er to make work with our products as easy as possible for you All the same the manual may contain technical inaccuracies and typing errors As a result of the rapid advance in the art we must also reserve the right to incorporate technical alterations and developments without separate advance notice That is why Connect2Car Inc does not give any warranty for the contents of the manual and for its co...

Page 5: ...tion about the wire its color type comments on its usage connection etc This helps to refresh things later and also it is used to remind you when changing controls in the SOFTDASH interface 1 3 2 SIMULATION MODE FOR RECIPES If you are going to be configuring or trying out a custom recipe that is not endorsed by Connect2Car make sure you test it out in the software simulation mode and observe and m...

Page 6: ...can be set so as to control how long the unit will wait for the user before engaging into the safe mode It is recommended that you do not disable the safe mode for accessories that control electro mechanical devices or features e g ignition windows sunroof linear actuators etc 1 4 Technical Support For all technical support please contact Connect2Car Inc via support connect2car com Your questions ...

Page 7: ...ocally as XML Extensible Markup Language formatted data files on the device which describe the functionality of the accessory The user interface to the vehicle is on the smart phone device The mobile device or PC acts as a tool to hold configure and deploy the recipes which are actually run in real time on the hardware controller while reporting status of activities back to the smart phone device ...

Page 8: ...2CAR COM 2 1 POSSIBLE SETUPS WITH THE MFC Figure 1 Overall MFC Capability NOTES Refer to the Software Manual to see a list of compatible phones PDA s and PC devices Also visit www connect2car com for the latest updates in compatibility of devices ...

Page 9: ...MFC INSTALLATION MANUAL Page 8 of 22 CONNECT2CAR COM 2 2 PHONE INTERFACE SETUP Figure 2 POSSIBLE PHONE INTERFACE CONFIGURATIONS 2 3 PDA INTERFACE SETUP Figure 3 POSSIBLE PDA DEVICE CONFIGURATIONS ...

Page 10: ...2CAR COM 2 4 PC INTERFACE SETUP Figure 4 POSSIBLE PC CARPC CONFIGURATIONS NOTES Refer to the Software Manual to see a list of compatible phones PDA s and PC devices Also visit www connect2car com for the latest updates in compatibility of devices ...

Page 11: ...gers 500mA max use external relays if needed POWER 12 18V USB CHARGING 5V max 5amps Bluetooth Serial Port Profile SPP Only Antenna Power Class 2 50ft Serial Port Mechanical 6 9 pin DSUB FEMALE connector MFC UNIT 6 75 x 4 x 1 25 PHYSICAL DIMENSIONS Bluetooth Antenna Module 3 x 1 5 x 75 with a 3 cable 3 3 GENERAL WIRING HARNESS CONFIGURATION Figure 5 MFC CONNECTOR DIAGRAM RED 12V DC Input BLACK Grou...

Page 12: ...e wires will be connected to the vehicle accessories such as door locks radio turn on trunk release etc They can all either send a or Signal depending on what the ACC source input wire is connected to P8 white wire See pg10 for details 3 4 1d Brown Tachometer Input With this wire connected to the vehicles tachometer signal wire it will allow you to get an RPM read out on the Connect2Car SOFTDASH S...

Page 13: ... live Bluetooth connection Note The Bluetooth data connection will be overridden disabled if the serial data cable is plugged in and the controlling computer device has the serial port activated 3 4 3 SERIAL DATA CONNECTOR This gives you local serial port control to the MFC device Use standard DB9 Female cable provided in the box An active serial port data connection with the MFC unit overrides th...

Page 14: ... ACC 6 OUT ve 500ma LT BLUE PIN 11 ACC 7 OUT ve 500ma BLUE PIN 12 ACC 8 OUT ve 500ma PURPLE M F C Car Battery GROUND BLACK WIRE TACHOMETER BROWN WIRE TACH 12V Serial Port PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN 9 PIN 10 PIN 11 PIN 12 DB9 M Serial Connector PINS 3 6 ACC 1 4 SOURCE INPUT OR ACC 1 OUTPUT Roll Windows Up ACC 2 OUTPUT Roll Windows Down ACC3 OUTPUT SUNROOF OPEN ACC 4 OUTPUT ...

Page 15: ...th Device POWER GROUND WINDOWS UP WINDOWS DOWN DOOR LOCK DOOR UNLOCK TACHOMETER INPUT PINS 3 6 ACC 1 4 SOURCE INPUT OR RADIO A C or OTHER ACCESSORIES TRUNK RELEASE ENGINE START ENGINE CUT OFF PIN 1 12V DC RED PIN 2 GROUND BLACK PIN 3 ACC 1 OUT max 24V 30A GREEN PIN 4 ACC 2 OUT max 24V 30A YELLOW PIN 5 ACC 3 OUT max 24V 30A PINK PIN 6 ACC 4 OUT max 24V 30A ORANGE PIN 7 TACHOMETER In BROWN PIN 8 ACC...

Page 16: ...allation setup however in this setup you waste a lot of accessory output connections due to the intermediate sections needed to achieve a single functionality Triggers in the picture are assumed to be setup depending on the purpose i e positive controlled or negative triggered setups Figure 8 Direct MFC Example Setup with Alarm add on ...

Page 17: ...l your hydraulics or air suspension in your car through a cell phone The diagram provided is based on a simple setup You can use this setup if best applied to your car or configure your own Figure 9 MFC Example Setup as Hydraulics Controller WARNING HIGH POWER RELAYS MUST BE USED IF THE HYDRAULIC USES 24V OVER 30 AMPS HIGH POWER RELAYS MUST BE USED IF THE AIR SUSPENSION USES 24V OVER 30 AMPS ...

Page 18: ...good understanding of the vehicle electrical system that they are working on The recommended remote start configuration utilizes tachometer as well as timed remote start The tachometer timing calibration is the basis of the ignition crank and the pulsed time out serves as the maximum possible crank time limit Connect2Car ACCEPTS NO RESPONSIBILTY FOR THE INSTALLATION OR CONFIGURATION OF THE REMOTE ...

Page 19: ...interface For the trigger accessory line set the maximum safety timeout for that line to be 1sec This means that no matter what recipe accessory configuration is assigned to that line the maximum time that output will be activated is 1 sec 5 1 2 DIRECT REMOTE START In this setup the MFC directly interfaces with all the necessary wires needed for a remote Start however in this configuration you use...

Page 20: ...e ignition wire and it is important that they all receive power in order for the remote start to work When testing an ignition wire it will read ground when in the key is in the accessory position and will be 12V when the key is in the run position and also in the crank position o Finding the Accessory wire wires The Accessory wire wires are not needed in order for the remote start to work however...

Page 21: ... tachometer system o SOFTWARE CONFIGURATION The direct Remote Start Recipe is included in the default download package of the software There are two types of button control settings included with the package One is a one touch remote start setup Touch to Start Touch to Stop and the other is a 2 stage self controlled remote start whereby the first stage activates all the accessories and the second ...

Page 22: ...tory relays you can avoid having to use your own just simply connect one of the outputs from the MFC to Lock and another one to Unlock as demonstrated below Figure 13 Connecting MFC to factory door triggers 5 3 MORE ACCESSORY CONFIGURATIONS 5 3 1 Parking Lights These wires can normally be found at the back of the switch n the kick panel running towards the rear of the vehicle or at the light itsel...

Page 23: ...completely rolled up One would have to implement an external cutoff even if the MFC is timed for the average rollup roll down time It is recommended you just use a standalone window module controller 5 3 5 Trunk release If your vehicle has a power hatch trunk release you can control it with your MFC by just triggering the trunk release line either negative or positive triggered 5 3 6 Air Ride or H...

Page 24: ...GHT 2006 Connect2Car Inc All rights reserved connect2car com Connect2Car Inc 540 Nepperhan Avenue Suite 580A Yonkers NY USA Tel 914 751 6426 Fax 914 239 3250 Connect2Car Tech Support US 914 239 3826 MFCFHM001 ...