ID.: 17-16-20-2979-10
20
3.2018
Table 2: Accessories
Accessories
Equivalent length in m
Knee
90° (Φ 200 mm)
3
Knee
90° (Φ 250 mm)
2
Reduction piece
Φ250 x Φ200
1
Wall blind
2
5.5 Connection of Condensation Outlet
By removing heat from air, condensation of air moisture also occurs in the heat pump.
Depending on air temperature and relative air humidity, the production of moisture from air
varies. In some cases, no moisture will be removed from air and in others, up to 10 litres of
condensed water may be produced.
Attachment
of
pipe
for
condensation outlet to the device.
Siphon
for
prevention
of
unpleasant odour seeping from
the drain.
The water condensation outlet pipe must be laid in a way, where the water may always freely
flow out. Connect outlet pipe with drain. Should this not be possible, ensure a collection
canister, which must be regularly emptied.
NOTE
When installing a condensation outlet, pay CAUTION that the pipe is always at a
downwards incline with a siphon and water pillar of at least 5 cm at the outflow.
This prevents the suction of unpleasant odours from outlets.
Summary of Contents for WP4 LF-502
Page 53: ...ID 17 16 20 2979 10 53 3 2018 ...
Page 54: ...ID 17 16 20 2979 10 54 3 2018 ...
Page 55: ...ID 17 16 20 2979 10 55 3 2018 ...