background image

 

 

 

 

 

Id.: 17-16-13-2960-03 | 7.2017 

 

14  MENU 

 

NOTE 

Contents and display of menus depend on model and configuration of device. 

 

Operational setting for  
control loop. 

 

Setting night mode: 

 

Fast heating of  
tap water. 

 

The  display  automatically  dims  in  moderate 
light. 

 

Temperature setting 
for tap water. 

 

The display automatically dims in low light. 

 

Display brightness 
*Brightness is automatically  
adjusted depending on  
Surrounding light. 

 

The display automatically dims in darkness. 

 

Night mode. 

 

Disable night mode. The display is always on. 

 

 

 

 

15  CHILD SAFETY LOCK 

 

 

The function is activated by pressing and 
holding buttons 

 and 

 simultaneously for 

2  seconds.  The  icon 

 is  displayed  in  the 

status  bar  to  indicate  an  active  child  safety 
lock function. Key operation is disabled. 
 
The function is deactivated by pressing and 
holding  buttons 

 and 

f  or  2  seconds 

simultaneously.  The  function  icon  in  status 
bar  disappears  and  normal  button  operation 
is restored. 

 

Child safety lock function prevents unauthorized access to the module. The function can also be 
used to prevent unwanted button triggering while front panel cleaning.

 

 

16  QUICK MENU 

 

 

The  “Quick  menu”  can  be  accessed  by 
pressing  the 

 button.  By  pressing  the 

 

button, we navigate between System view and 
Weather  forecast  menus.  Weather  can  be 
viewed for the next two days. By pressing  
the 

 button, we return to the Main menu. 

 

OPOMBA 

The Weather is only shown if the device is connected to the Internet and the location of the 
device is set at the web interface Home Cloud. 

 
 
 
 
 
 
 
 

2

2

sec

 

Summary of Contents for KT-2

Page 1: ...Installation instruction and user manual KT 2 Spatial corrector The manual has to be handed over to the end user after installation ID 17 16 13 2960 03 1 2017 EN ...

Page 2: ... 03 7 2017 Printed in Slovenia copyright Kronoterm d o o This document is copyrighted Any use outside the provisions of the copyright law without the permission of Kronoterm d o o is illegal and punishable by law All previous versions of this document are void We reserve the right to make changes and printing errors ...

Page 3: ...age temperature of other rooms hallway living room The spatial corrector KT 2 is designed for installation on a flush mounted electrical socket 3M GW 24 403 PM The spatial corrector is used for fixed installation in closed and dry rooms Recommended mounting height is between 1 2 1 5 m from the ground Do not expose the spatial corrector KT 2 to direct sunlight do not install it in the area of air c...

Page 4: ...bles from the spatial corrector KT 2 connected to terminals A B GND and 12 V to the RJ 45 connector Prepare the RJ 45 connector the same way as the one in the wiring diagram below Connect it to the connecting terminal TS on the PLC in electric closet controller TERMOTRONIC UTP link between RJ 45 connector and KT 2 TIA EIA 568A connection of connector Cable colors RJ 45 A B GND 12V KT 1 1 2345 6 78...

Page 5: ...nfirms valid settings with a multi tone beep 9 SYNCHRONISATION The device is synchronising wait a few minutes After a successful synchronisation the control panel is ready for use see Qick user guide NOTE Only one spatial corrector can control an individual control loop Incorrect operation occurs if two spatial correctors are installed on the same control loop 10 CHNGE OR RESETTING OF CONTROL LOOP...

Page 6: ...set is displayed when the or arrow is pressed The temperature is highlighted with an orange border Fast heating of tap water Fail safe anti freeze mode is active Device maintenance of required Desired room temperature can be set by pressing the arrow again the setting is confirmed by pressing the icon or is automatically confirmed after 8 seconds Child safety lock is active Multiple alarms errors ...

Page 7: ...played in the status bar to indicate an active child safety lock function Key operation is disabled The function is deactivated by pressing and holding buttons and f or 2 seconds simultaneously The function icon in status bar disappears and normal button operation is restored Child safety lock function prevents unauthorized access to the module The function can also be used to prevent unwanted but...

Page 8: ...sult our technical assistance http www kronoterm com servis 18 Technical Device Information Dimensions HxWxD 80x80x8 6 mm The resolution of the temperature sensor 0 1 C Adjustable range 17 27 C Modbus RS485 connection Max 4 x KT 2 units can be connected to TT3000 Weather symbol Highest day time temperature forecast Air Humidity Day of the week Lowest night time temperature forecas Device current o...

Page 9: ...9 Id 17 16 13 2960 03 7 2017 ...

Page 10: ...Id 17 16 13 2960 03 7 2017 10 ...

Page 11: ...11 Id 17 16 13 2960 03 7 2017 ...

Page 12: ...nd place of production Kronoterm d o o Trnava 5e 3303 Gomilsko Tel 00386 3 703 16 20 Fax 00386 3 703 16 33 Web page www kronoterm com E mail info kronoterm com Customer support and service 00386 3 703 16 26 E mail servis kronoterm com ...

Reviews: