VII - 7
Maintenance
AUS
EIN
4
3
5
2
1
7.7
Maintenance instructions for the
hydraulic system
7.7.1 High-pressure filter
All Series XL loading wagons with the
operator-friendly
hydraulic unit are fitted with a high-pressure filter in the
high-pressure pipework to the valve unit.
Change the filter (3) after each season.
Changing the filter element
• Switch the hydraulic system to the non-pressurised
state.
Place a vessel of sufficient capacity
underneath to hold the escaping oil.
• Slacken the filter bottom section (4) using screw
wrench SW27.
• Remove the filter bottom section (4) and shake out
the remaining oil.
• Clean the filter bottom section (4).
• Pull out the old filter element (3).
• Push the new filter element (3) onto the valve collar.
• Check the O-ring (2) on the filter bottom section (4).
If the O-ring is damaged, replace it with a
new one.
• Replace the filter bottom section and screw it in.
• Tighten to the end stop in the filter top section (1).
• Pressurise the hydraulic system and check for leaks.
Summary of Contents for 5XL-R/GL
Page 4: ...Foreword ...
Page 8: ...4 Contents ...
Page 12: ...I 4 Generalinformation ...
Page 17: ...II 5 Safety ...
Page 24: ...II 12 Safety ...
Page 48: ...IV 6 Control Unit 4 5 Manual mode 4 5 1 Basic screen Loading operation ZX000008_1 ...
Page 84: ...IV 42 Control Unit ...
Page 92: ...IV 50 ISO operation ...
Page 104: ...VI 10 Hydraulic system ...
Page 124: ...VII 20 Maintenance ...
Page 126: ...VIII 2 Overwintering ...
Page 128: ...IX 2 Recommissioning ...
Page 130: ...X 2 Faults causes and removal ...
Page 152: ...A 22 Appendix ...
Page 153: ...A 23 Appendix ...