5. MAINTENANCE
5.1
Routine maintenance
WARNING: The machine is not protected against pressurized water jets. Do not use
pressure cleaning system against the machine.
It is recommended to contact the seller of chemicals for proper cleaning instructions,
in order to have detailed indications on methods and products for the correct periodical
machine sanitation.
Do not use bleach or chlorine based detergents.
Daily cleaning is needed to ensure that the machine runs perfectly. The following shall be
carried out:
• Turn the machine in
"STAND-BY"
mode, by pressing the push-button
"B"
of the control
panel (see chap. 2).
• Remove the surface fi lters and clean them under running water (see pict. 2). Drain the
sump water (see chap. 2.2.3).
• Remove the overfl ow
• Remove the pump fi lter and clean with a brush and a water shower.
• Remove the arms by loosening the fi xing screws, and thoroughly clean them, and the
nozzles under running water.
• Remove the heat exchanger fi lter (if installed) and clean it under running water (see pict. 3).
• Reassemble the parts and reposition the wash pipes fi rmly in place.
• Clean the tank very carefully, using a water shower.
• It is recommended to leave the machine door open at the end of the day.
• Automatic cycle of machine self-cleaning/rinsing: recommended at each day end.
With the machine on
"STAND-BY"
mode, remove the overfl ow pipe and, when the tank
is empty, press the START “A” key; an automatic cycle of 60 seconds will start, after this
the machine will be in
"STAND-BY"
mode.
• Shut the water valve.