EN
page 27
INSTALLER SECTION
WARNINGS:
Once installation is complete, it is recommended to detach the installer’s guide section of
this manual for future reference
.
1. MACHINE INSTALLATION
1.1 Receiving product
After removing the packaging, make sure that the apparatus was not damaged during tran-
sportation. If this should be the case, notify the seller of the defect. For packaging disposal
see chap. 9.
1.2 Water connection
Connect the machine water supply with a stop valve that can quickly and completely
turn off water flow.
Make sure that the water supply system is within the parameters reported in tab. 1.
If the water system pressure is above 4 BARS (400 KPa), a pressure reducer is recom-
mended.
It is compulsory to install a water-softner for water with average hardness above
10°f.
Dishes/objects will be cleaner and the machine will last longer.
Each machine is supplied with a rubber water load tube with a 3/4"F threaded connection.
It is recommended to connect the tube to water supply systems that do not exceed 55°C,
if connected to hot water.
Connect the supplied machine draining tube to the connector located under the tank, making
sure that the water flows freely (giving, therefore, minimum slope).
The drain tube shall always be connected to a siphon (Ø) in order to prevent the release of
odours.
The MAXIMUM drain permitted height is 10cm.
1.3 Electrical connection
The electrical connection shall be carried out in accordance to the laws in force.
Make sure that the line voltage is the same as that written on the machine plate
.
Apply a
suitable magneto-thermic omni polar switch measured in accordance to absorption
and that is equipped with a contact opening of at least 3 mm (always turn the machine
off with this switch). This is the only switch which guarantees total electric supply
system isolation.
This switch shall be solely and exclusively used for this purpose and installed in the imme
-
diate vicinity
.
Make sure that the facility is equipped with efficient grounding
.
Moreover, the machine has a clamp at the back indicated by the symbol (see fig. 1) that is
used for equipotent connection among different apparatuses. The maximum power expresses
in watts (W) and amperes (A) is located on the serial number plate for line measurement,
cable and switches
.
N.B.:
for machines cable types H05RN-F or H07RN-F must be used or replace with
others which correspond to the regulations of the country where the ware-washer is
installed. A 4mm² section for voltage 380-415V3~, and a 6mm² section for voltage
220-240V3~.
The replacement of the cable must be carried out by specialized
personnel only.
The seller/importer/installer must adapt the supply cable isolation class in function to the
work environment respecting the Technical Regulations in force
.
pict. 1
Pressure table
Min.
Max.
kPa
kPa
Static Pressure
250
400
Dynamic Pressure
200
300
Hardness
2°f
10°f
table 1