10. ECOLOGICAL ASPECTS
10.1 Recommendations for optimal use of energy, water and additives
Use the machine fully loaded when possible.
This shall prevent detergent, rinse aid, water and energy consumption waste.
Detergent and rinse-aids
Use detergents and rinse-aid chemicals with high biodegradability, to best respect the en-
vironment. Verify proper dosage in relation to water hardness at least once a year. Excess
product pollutes rivers and seas while an insuffi cient dose results in unsatisfactory dish
washing and/or hygiene.
Boiler and Tank temperatures
The boiler and tank temperatures are set by the manufacturer in order to obtain the best
washing results with detergents on the market. The temperatures can be reset by the installer
in relation to your detergent.
Pre-washing
Carefully pre-wash with a moderate amount of water at room temperature to facilitate the
removal of animal fats.
To remove encrusted materials warm water soaking is recommended.
Note:
Wash objects as soon as possible to avoid deposits from drying and compromise effective
washing.
For effective washing routine dishwasher cleaning and maintenance is advised (see chap.
8).
The disregard of the points listed above and of any the information contained in this
manual can cause energy, water and detergent waste with a subsequent increase in
cost and/or performance reduction.
11. DETECTION AND DISPLAY OF ALLARMS AND FAULTS
11.1 50570/G dispaly detection
The following faults are managed and displayed
:
•
probes: when there is a short circuit or a break, or when the measured temperatures are
below 0°C or above 125°C
;
•
boiler overheating: when the boiler temperature exceeds 105°C
;
•
tank overheating; when the tank temperature exceeds 90°C
;
•
lack of boiler heating: if the set temperature in the boiler has not been reached after 30
min from activation
;
•
lack of tank heating: if the set temperature in the tank has not been reached after 1 hour
from activation
;
•
water load: if water loading is not complete by the set time (parameter 8)
;
•
open door alarm: if the door is opened during the cycle
;
•
boiler load: if boiler loading is not complete by the set time (parameter 9).
If the user does not comply with the regulations he/she shall be subject to the penalties
foreseen by each member state.
Disconnect electricity and water before disposal.
Cut the electrical cable to ensure that further use is impossible.
All metal parts are recyclable as they are made of stainless steel.
Recyclable plastic parts are marked with the plastic material symbol.