Primary head VFS 1000 (I)
Versions and meter sizes
Pressure ratings
see “Dimensions” Table
(Note operating limits given in DIN 2501 and ANSI B 16.5)
Sandwich design to ... DIN 19205
DN 25 to 150
ANSI
1”
to
6”
Flange connections to ...DIN 2501
DN 10S to 200
ANSI B 16.5
3/8”S TO 8”
Groove joint to...
DIN 2515
DN 25 TO 150
(Optional) ANSI
1” to 6”
Process and ambient temperature
see
Diagram
III
1
Housing
SR.NO. DESCRIPTION MATERIAL REMARKS
GASKET, TEFLON (PTFE)
GASKET, STYLE AF-160, NON
ASBESTOS
5.
Gaskets
GASKET, STYLE AF-139, NON
ASBESTOS Any one as per application
M10 = 5.5 kg - m
M8 = 2 kg - m
4.
Bluff body metal seal
C ring Inconel Ni plated Once used metal C ring shoul
d
not be used again. Tightening
torques for new seals are
m
M6 = 1.5kg -
3.
a. upto 180 deg C(356deg.F) Viton O ring Non steam applications
Seals
b. upto 220deg C(428deg.F) Kalrez 4079 O ring Non steam applications
c. upto 240deg C(464deg.F) Parofluor O ring Steam applications
2.
Vortex shedding body
Unalloyed Titanium (No.3.7035) as standard
Stainless Steel, A351 CF3M (316L) Upto size DN100/4''
Stainless Steel, A351 CF8 (304) From DN150/6'' to DN200/8''
Materials
Max. allowable operating pressure
(primary head) 40 bar (580 psig), optionally upto 100 bar (1450 psig)
Hazardous Duty Versions: FM, CSA, PTB approvals pending.
Error limits
Measuring error (in linear range)
± 1 % of measured value for DN 25 (1”) & above
± 2 % of measured value for DN 10S (3/8”S) to DN 20 (3/4”)
Repeatability (in measuring range)
± 0.5 % of measured value
Temperature Error
- 0.025 % of measured value per 10Kelvin (50
o
F) variation
Pressure loss
D
p
at normal conditions
for air[1.013 bar (14.7psig)/0
o
c(32
o
F) /
r
n
= 1.29 kg/m(0.081 lbs/ft)]
see Diagram I
for water [20
o
C (68
o
F) /
r
n
= 998.2 kg/m (63.32 lbs/ft)]
see Diagram II DP = Pressure loss in Pa
at operating conditions
C = A constant
for
gases
and
liquid
DP=
C
*
Q
v
2
*
r
op
(values:
see
Table)
Qv = Flow rate in m/hr
for saturated steam
DP = C * Qm2 Qm = Flow rate in kg/hr
r
op
r
op
=operating density in kg/m