TECHNICAL DATA
6
27
SD 200 W/R
www.krohne.com
01/2020 - 4003851304 - MA SD 200 W/R R04 en
6.1 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Downloadcenter).
Design
Design
Design
Design
Type
High intensity reflective numeric and alphanumeric LCD, UV-resistant.
Digits
4 digits 26 mm / 1" and 11 digits with 8 mm / 0.31". Various symbols and measuring
units.
Refresh rate
1 times/sec.
Wall mount
GRP (Glass fibre Reinforced Polyamide) with polycarbonate window, silicone
gaskets. UV stabilised and flame retardant materials.
Keypad
Three industrial micro-switch keys. UV-resistant
silicone keypad.
Dimensions LxHxD
130 x 120 x 75 mm / 5.10
”
x 4.72
”
x 2.95
”
Classification
IP67 / NEMA4X
Cable gland
M16
Rack mount
Die-cast aluminium housing with polycarbonate window, silicone gaskets. UV
stabilised and flame retardant materials.
Keypad
Three industrial micro-switch keys. UV-resistant
silicone keypad.
Dimensions LxHxD
144 x 72 x 46 mm / 5.67
”
x 2.83
”
x 1.81
”
Classification
IP65 / NEMA4
Panel cut-out
138 x 68 mm / 5.43
”
x 2.68
”
Painting
UV-resistant 2-component industrial painting
Operating temperature
Operating temperature
Operating temperature
Operating temperature
Operational
-30
°
C...+80
°
C / -22
°
F...+176
°
F
Intrinsically Safe
-30
°
C...+70
°
C / -22
°
F...+158
°
F
Power requirements
Power requirements
Power requirements
Power requirements
Type
Input loop powered from 4-20mA signal input. Voltage drop max. 2V DC.
Note I.S. application
For intrinsically safe applications, consult the safety values in the certificate.
Terminal connections
Terminal connections
Terminal connections
Terminal connections
Type
Removable plug-in terminal strips. Wire max. 1.5mm
2
/ 16 AWG.
Data protection
Data protection
Data protection
Data protection
Type
Data backup of all setting. Data retention at least 10 years.
Password