background image

Loop powered indicator

(SW.REV. 03.01.x)

SD 200 W/R

SD 200 W/R

SD 200 W/R

SD 200 W/R

Handbook

Handbook

Handbook

Handbook

© KROHNE 01/2020 - 4003851304 - MA SD 200 W/R R04 en

Summary of Contents for SD 200 W/R

Page 1: ...Loop powered indicator SW REV 03 01 x SD 200 W R SD 200 W R SD 200 W R SD 200 W R Handbook Handbook Handbook Handbook KROHNE 01 2020 4003851304 MA SD 200 W R R04 en...

Page 2: ...or any part thereof without the prior written authorisation of KROHNE Messtechnik GmbH Subject to change without notice 2 www krohne com 01 2020 4003851304 MA SD 200 W R R04 en Copyright 2020 by KROHN...

Page 3: ...eplate SD 200 R 11 2 4 Nameplate SD 200 W 12 3 Installation 13 3 1 General notes on installation 13 3 2 Storage and transport 13 3 3 Installation 14 3 4 Connection with junction box SJB 200 W 15 3 5 C...

Page 4: ...CONTENTS 4 www krohne com 01 2020 4003851304 MA SD 200 W R R04 en SD 200 W R 6 Technical data 27 6 1 Technical data 27 6 2 Dimensions 29 7 Notes 30...

Page 5: ...ing CAUTION Responsibility for the use of the measuring devices with regard to suitability intended use and corrosion resistance of the used materials against the measured fluid lies solely with the o...

Page 6: ...the Internet e g when communicating by e mail may involve gaps in security It is not possible to protect such data completely against access by third parties We hereby expressly prohibit the use of t...

Page 7: ...prevent any injury to the user or damage to the device it is essential that you read the information in this document and observe applicable national standards safety requirements and accident preven...

Page 8: ...ngs must be observed without fail Even partial disregard of this warning can lead to serious health problems and even death There is also the risk of seriously damaging the device or parts of the oper...

Page 9: ...of rough handling Report damage to the carrier and to the local office of the manufacturer INFORMATION Do a check of the packing list to make sure that you have all the elements given in the order IN...

Page 10: ...gure 2 2 Construction of the indicator 1 Measuring value 2 Measuring parameter 3 Status information 4 Operation key CLEAR 5 Operation key SELECT 6 Operation key PROG ENTER Figure 2 3 Construction of t...

Page 11: ...R R04 en 2 3 Nameplate SD 200 R Figure 2 4 Example for a nameplate 1 Order code 2 Temperature ambient 3 Manufacturer 4 Device name 5 Serial number 6 CE marking 7 Power supply INFORMATION Look at the...

Page 12: ...erial number 3 Ingress protection 4 Temperature ambient 5 Manufacturer 6 Power supply 7 Order code 8 CE marking Figure 2 6 Example for a nameplate outside 1 Product name 2 Ingress protection 3 Order c...

Page 13: ...wiring diagrams DANGER Protection against accidental contact is no longer assured when the housing cover is removed or the cabinet has been opened The housing may only be opened by trained personnel W...

Page 14: ...Even an IP67 NEMA 4X enclosure should NEVER be exposed to strongly varying weather conditions When used in very cold surroundings or varying climatic conditions with high humidity above 90 annual mean...

Page 15: ...nergise the cables of the power supply before you start any installation works Always keep the housing of the device well closed if you do not perform any installation works The function of the housin...

Page 16: ...SJB 200 W with SMARTPAT sensor display and without integrated HART resistor right side SJB 200 W with SMARTPAT sensor integrated HART resistor and display SJB 200 W with SMARTPAT sensor display and w...

Page 17: ...ted to the connection facility terminal S Consider the information mentioned in the supplementary instruction of the SMARTPAT sensor Figure 3 3 Connection without SJB 200 W only with wall mounting ver...

Page 18: ...r supply comply with the requirements of the device CAUTION Installation assembly start up and maintenance may only be performed by appropriately trained personnel The regional occupational health and...

Page 19: ...1 5 mA the value 9999 and Error high will be displayed If the input current is above 25 mA the value 9999 and Error SC short circuit will be displayed 4 4 Configuration Configuration of the SD 200 W R...

Page 20: ...value by pressing or Press to confirm the value selection To change a value use to select the digits and to increase that value To select a setting both and can be used When data is changed but ENTER...

Page 21: ...t the span has to be adapted as well the calculation is not done automatically 12 Decimals This setting determines the number of digits following the decimal point The following can be selected 0000 1...

Page 22: ...TUNED will be displayed as soon as the calibration is completed From that moment the value must be more than the calibrated value before the signal will be processed DFLT with this setting the factory...

Page 23: ...to and including 4 digits can be programmed 26 Tag number For identification of the unit and communication purposes a unique tag number of maximum 7 digits can be entered 2 Others software version 03...

Page 24: ...ollowing maintenance measures Check the housing connector and the feed lines for corrosion and or damage Check the entire device for dust deposits Check the input output wiring for reliability and agi...

Page 25: ...the health and safety of the personnel the manufacturer may only handle test and repair returned devices that have been in contact with products without risk to personnel and environment This means th...

Page 26: ...ice when it is returned Date Signature Stamp LEGAL NOTICE Disposal must be carried out in accordance with legislation applicable in your country Separate collection of WEEE Waste Electrical and Electr...

Page 27: ...IP67 NEMA4X Cable gland M16 Rack mount Die cast aluminium housing with polycarbonate window silicone gaskets UV stabilised and flame retardant materials Keypad Three industrial micro switch keys UV re...

Page 28: ...FAU S cm S m mS m S m mbar bar psi mm cm m inch ft mmwc cmwc mwc inwc ftwc Decimals 0 1 2 3 Approvals and certificates Approvals and certificates Approvals and certificates Approvals and certificates...

Page 29: ...04 en 6 2 Dimensions Figure 6 1 Dimensions SD 200 R Dimensions mm Dimensions inch a 72 2 83 b 144 5 67 c 30 1 18 d 16 0 63 e 68 2 68 f 138 5 43 Figure 6 2 Dimensions SD 200 W Dimensions mm Dimensions...

Page 30: ...7 NOTES 30 SD 200 W R www krohne com 01 2020 4003851304 MA SD 200 W R R04 en...

Page 31: ...NOTES 7 31 SD 200 W R www krohne com 01 2020 4003851304 MA SD 200 W R R04 en...

Page 32: ...Services Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 10389 info krohne com KROHNE 01 2020 4003851304 MA SD 200 W R R04 en Subject to...

Reviews: