INSTALLATION
3
27
OPTISWIRL 4200
www.krohne.com
02/2022 - 4003930810 - MA OPTISWIRL4200 R10 en
3.4 Installation conditions
INFORMATION!
For accurate volumetric flow measurement the measuring device needs a completely filled pipe
and a fully developed flow profile.
CAUTION!
Any vibrations may distort the measuring result. That is why any vibrations in the pipeline must
be prevented through suitable measures.
CAUTION!
Procedures to carry out before installing the device:
•
Nominal diameter of connection pipe flange = nominal flange diameter of pipe!
•
Use flanges with smooth holes, e.g. welding neck flanges.
•
Align carefully the holes of the connecting flange and the flowmeter flange.
•
Check the compatibility of the gasket material with the process product.
•
Make sure that the gaskets are arranged concentrically. The flange gaskets must not project
into the pipe cross-section.
•
The flanges have to be concentric.
•
There must not be any pipe bends, valves, flaps or other internals in the immediate inlet run.
•
Devices in sandwich version may only be installed using centering rings.
•
Never install the device directly behind piston compressors or rotary piston meters.
•
The device must not be heated by radiated heat (e.g. exposure to the sun) to an electronics
housing surface temperature above the maximum permissible ambient temperature. If it is
necessary to prevent damage from heat sources, a heat protection (e.g. sun shade) has to be
installed.
•
Do not lay signal cables directly next to cables for the power supply.
•
At product temperatures or ambient temperatures >+65°C / +149°F, a connection cable and
cable glands with a minimum service temperature of +80°C / +176°F must be used.
INFORMATION!
If there is a risk of water hammers in steam networks, appropriate condensate separators must
be installed. Suitable measures must be taken to avoid water cavitation if it is a possible risk.
INFORMATION!
For devices with built-in pressure sensor, suitable measures must be taken to ensure that the
maximum operating temperature of +110°C / +230°F is not exceeded at the pressure sensor.
Additionally the pressure sensor must be protected against effects of frost.