44
9 Supplement
OPTISOUND 3020 C • Two-wire 4 … 20 mA/HART
30507-EN-190318
9 Supplement
9.1 Technical data
Note for approved instruments
The technical data in the respective safety instructions are valid for approved instruments (e.g. with
Ex approval). These data can differ from the data listed herein, for example regarding the process
conditions or the voltage supply.
General data
Materials, wetted parts
Ʋ Transducer
PVDF
Ʋ Seal transducer/process fitting
EPDM, FKM
Ʋ Process fitting G2, DIN 3852-A-B
PVDF
Ʋ Process fitting 2 NPT, ASME B1.20.1 PVDF
Materials, non-wetted parts
Ʋ Housing
Plastic PBT (polyester), Alu die-casting, powder-coated,
316L
Ʋ Seal, housing lid
Silicone SI 850 R
Ʋ Inspection window housing cover
Polycarbonate (UL-746-C listed), glass
8)
Ʋ Ground terminal
316Ti/316L
Ʋ Cable gland
PA, stainless steel, brass
Ʋ Sealing, cable gland
NBR
Ʋ Blind plug, cable gland
PA
Weight
1.8 … 4 kg (4 … 8.8 lbs), depending on the process
fitting and housing
Max. torque mounting boss
25 Nm (18.44 lbf ft)
Input variable
Measured variable
distance between lower edge of the transducer and
product surface
Measuring range
Ʋ Liquids
up to 8 m (26.25 ft)
Ʋ Bulk solids
up to 3.5 m (11.48 ft)
Dead zone
0.4 m (1.312 ft)
Deviation (according to DIN EN 60770-1)
Deviation
9)
≤ 4 mm (meas. distance > 2.0 m/6.562 ft)
8)
Glass (with Aluminium and stainless steel precision casting housing)
9)
Incl. non-linearity, hysteresis and non-repeatability.