DEVICE DESCRIPTION
2
7
DK32 DK34
www.krohne.com
04/2015 - 4000422303 AD DK32/34 II2G R03 en
2.8 Electrical data
The electronic signal output may only be connected to intrinsically safe circuits. Depending on
the instrument design, the following maximum values apply per circuit:
Design DK3./../.././../A
–
Ex
Irrespective of the instrument design the following values are to be observed for each
intrinsically safe circuit in case of interconnection:
U
i
16 VDC
I
i
25 mA
P
i
64 mW
C
i
150 nF
L
i
150
µ
H