BM 70 M
71
PC-CAT allows convenient remote control of all functions of the signal converter. The vessel can
be shown in schematic form together with the associated measured values and the measured
spectrum. A trend graph of the output signal and threshold signal strength is also provided. All
relevant instrument data can be recorded in the form of a data set small enough to be stored on a
floppy disk or transferred electronically. Stored data can also be used for configuring other units
of the BM 70 product line.
PC-CAT files can later be used to analyse the performance of the level gauge. All graphs and
screens can be exported a word processing systems or other programs.
The customer’s PC containing PC-CAT is connected to the current output via the supplied PC
adapter, max. distance from the level gauge: 1000 m or 3300 ft. The PC adapter has no effect on
in-line instruments such as milliamperemeters, recorders, etc., connected to the current output.
9 Power
supply
9.1
Options, technical data
A choice is offered of 2 supply power versions:
Version
Voltage U
Tolerance
= voltage
range
Frequency Power
(typical) *
max. ripple /
harmonics
24V DC/
AC
24 V DC
-25% +30%
18-31.2 V
-
7.5 - 10 W
within limits
of tolerance
24 V AC
-25% +10%
18-26.4 V
45-66 Hz
10 VA
10%
115/230
V AC
115 V AC
-25% +10%
85-127 V
45-66 Hz
12 VA
10%
230 V AC
-25% +10%
170-254 V
45-66 Hz
12 VA
10%
* Hazardous-duty limit: 20W / 40 VA
Summary of Contents for BM 70 M Series
Page 75: ...BM 70 M 75 10 Certificates and approvals 10 1 Declaration of Conformity...
Page 83: ...BM 70 M 83 Annex C Spare parts...
Page 84: ...84 BM 70 M...
Page 85: ...BM 70 M 85...
Page 102: ...16 BM 70M EEx BM 70Mi EEx 11 Approvals...
Page 103: ...BM 70M EEx BM 70Mi EEx 17...
Page 104: ...18 BM 70M EEx BM 70Mi EEx...
Page 105: ...BM 70M EEx BM 70Mi EEx 19...
Page 106: ...20 BM 70M EEx BM 70Mi EEx...
Page 107: ...BM 70M EEx BM 70Mi EEx 21...
Page 108: ...22 BM 70M EEx BM 70Mi EEx...