Spray pattern
Error
Cause
Remedy
Fluid jet comes out in
spurts or rapid bursts
n
Insufficient mate-
rial supply
n
Increase material
supply
n
Blocked fluid path
n
Clean
n
Loose or dam-
aged fluid nozzle
n
Tighten or replace
(
‘Changing the
fluid nozzle and
the air nozzle’
on page 29
n
Worn needle seal
n
Replace needle
seal (
8.6 ‘Changing the
needle seals’
on page 34
Leakage on the
clamping screw
n
Needle seal
defective
n
Replace needle
seal (
8.6 ‘Changing the
needle seals’
on page 34
Fluid nozzle drips
n
Worn or damaged
fluid needle
n
Change fluid
needle (
‘Changing the
fluid needle’
on page 30
n
Dirty or damaged
fluid nozzle
n
‘Cleaning the
automatic spray
gun’ on page 27
or replace fluid
nozzle (
‘Changing the
fluid nozzle and
the air nozzle’
on page 29
-
Spray pattern change
after reassembly.
Atomisers for round
and flat jets can no
longer be regulated
separately
n
Air distributor ring
installed wrong
way
n
Remove air dis-
tributor ring and
install correctly
Operating instructions