7.3
Changing the air and fluid nozzles
Removing the nozzles
1.
Clean automatic spray gun (
Chapter 7.2 ‘Cleaning spray guns’ on page 25
)
Fig. 10: Changing the nozzles
2.
WARNING!
The closing piece (Fig. 10/5) is under spring force!
Carefully unscrew the closing piece (Fig. 10/5).
3.
Loosen clamping nut (Fig. 10/1).
4.
Remove the air nozzle (Fig. 10/2).
5.
Unscrew fluid nozzle (Fig. 10/3).
Always change the fluid nozzle (Fig. 10/3) and fluid needle (Fig. 10/4) at the same time
(
Chapter 7.4 ‘Changing the fluid needle’ on page 27).
Attaching the nozzles
1.
Tighten the fluid nozzle (Fig. 10/3).
2.
Attach the air nozzle (Fig. 10/2) and tighten it with the clamping nut (Fig. 10/1).
3.
Screw on the closing piece (Fig. 10/5).
Operating instructions
T-Dok-144-GB-Rev.1
[email protected], www.krautzberger.com