Step 2: Install & secure spout

Install spout (D) through hole 
in countertop or sink. Attach 
rubber & metal U-washer (E1) 
and mounting nut (E2). Adjust 
spout (D) to proper position 
and tighten mounting nut (E2) 
with adjustable wrench. Secure 
T-union (F) onto supply line of 
spout (D). Tighten T-union (F) 
with adjustable wrench

Step 3: Install & secure hot and cold handle valves

Install hot and cold handle valves 
(A & B) through hole in countertop 
or sink. Attach rubber & metal 
washer (C1) and mounting nut 
(C2) to the threaded mounting 
pipe. From underneath the 
countertop or sink, tighten 
mounting nut (C2) onto valves (A 
& B) with adjustable wrench until 
snug. Secure mounting nut (C2) by 
tightening mounting screws (C3) 
with a Phillips head screwdriver

1

2

3

1 1/4-18UNF-2A

9/16”-18UNEF

27mm ~ 41.3mm

1 1/16

”  ~ 1 5/8”

7A

8B
8C

8D

8A

9/16”-18UNEF

27mm ~ 41.3mm

1 1/16

”  ~ 1 5/8”

7A

8B

8C

8D

8A

7A

8B
8C

8D

8A

4

5

H

A

D

D

A

C1
C2

C3

B

E1

E2

F

B

C

C

F

E

H

A

B

H

G

G

I

J

F

1

2

3

1 1/4-18UNF-2A

9/16”-18UNEF

27mm ~ 41.3mm

1 1/16

”  ~ 1 5/8”

7A

8B
8C

8D

8A

9/16”-18UNEF

27mm ~ 41.3mm

1 1/16

”  ~ 1 5/8”

7A

8B

8C

8D

8A

7A

8B
8C

8D

8A

4

5

H

A

D

D

A

C1
C2

C3

B

E1

E2

F

B

C

C

F

E

H

A

B

H

G

G

I

J

F

Summary of Contents for Seda FUS-1823

Page 1: ...INSTALLATION MANUAL www kraususa com I toll free 1 800 775 0703 I 2014 2015 Kraus USA Inc Seda 8 Widespread 2 Handle Faucet FUS 1823 ...

Page 2: ...lcome any questions or comments you may have and will be glad to assist you in the future For more information about Kraus products please visit our website at www kraususa com Please register your new Kraus product at the following web address in order to activate the warranty and receive the full benefit of customer support www kraususa com registration Sincerely Kraus Customer Service Departmen...

Page 3: ...e old faucet to release any built up pressure Remove existing faucet Clean sink or countertop to remove any debris plumber s putty or silicone Place bucket under angle stops Turn on angle stops to flush any debris prior to installing new plumbing Shut off angle stops Max countertop thickness 1 3 8 Tools you will need Adjustable Wrench Phillips Screwdriver Safety Goggles Bucket 8 5 16 1 1 4 18UNF 2...

Page 4: ...ot Handle Valve B Cold Handle Valve C Hot Cold Handle Mounting Hardware C1 Rubber Metal Washer C2 Mounting Nut C3 Mounting Screws D Spout E Spout Mounting Hardware E1 Rubber Metal U Washer E2 Mounting Nut F T Union G Hot Cold Waterlines H 3 8 in OD x 1 2 in IPS Waterlines I Aerator J Aerator Key K Hex Wrench ...

Page 5: ...cet Dimensions Step 1 Remove mounting hardware and T union Remove T union F and mounting hardware E from spout D Remove mounting hardware C from hot and cold handle valves A B 1 2 1 1 4 18UNF 2A 9 16 18UNEF 27mm 41 3mm 1 1 16 1 5 8 7A 8B 8C 8D 8A 7A 8B 8C 8D 8A 7A 8B 8C 8D 8A A D D A C1 C2 C3 B E1 E2 F C C F E ...

Page 6: ...old handle valves A B through hole in countertop or sink Attach rubber metal washer C1 and mounting nut C2 to the threaded mounting pipe From underneath the countertop or sink tighten mounting nut C2 onto valves A B with adjustable wrench until snug Secure mounting nut C2 by tightening mounting screws C3 with a Phillips head screwdriver 2 3 1 1 4 18UNF 2A 9 16 18UNEF 27mm 41 3mm 1 1 16 1 5 8 9 16 ...

Page 7: ... A Hot Side Left B Cold Side Right Secure other end of waterlines to angle stops Tighten all ends with adjustable wrench until snug Turn on angle stops and check for leaks DO NOT TURN FAUCET ON Remove adjustable aerator I with aerator key J Turn water on for 1 minute to remove any debris Reassemble adjustable aerator I 4 5 H H A B H G G I J F 2 3 1 1 4 18UNF 2A 9 16 18UNEF 9 16 18UNEF 27mm 41 3mm ...

Page 8: ...e 3 Set Screw 4 Cover Button 5 Hot Cartridge 6 Hot Valve 7 Rubber Metal Washer 8 Mounting Nut 9 Mounting Screw 10 Adjustable Aerator 11 Rubber Metal U Washer 12 Mounting Nut 13 T Union 14 Cold Cartridge 15 Cold Valve 16 Hot Cold Waterlines 17 3 8 in OD x 1 2 in IPS Waterlines 18 Aerator Key 19 Hex Wrench ...

Page 9: ...ove aerator 10 and clean out debris Water will not shut off completely Hot or cold cartridge 5 or 14 may need to be adjusted or replaced Remove cover button 4 Loosen set screw 3 with hex wrench 19 Remove handle 1 or 2 Remove hot or cold cartridge 5 or 14 with adjustable wrench Check for cracks Care Maintenance To keep the product clean shining follow the steps below 1 Rinse with clean water dry wi...

Page 10: ...se service and maintenance If Kraus is unable to provide a replacement and repair is not practical or cannot be made in timely fashion Kraus may elect to refund the purchase price in exchange for the return of the product CONDITIONS AND EXCLUSIONS Like other home fixtures Kraus products will require light maintenance to ensure proper function We provide you with complete knowledge to perform this ...

Page 11: ...des freight costs cartridge replacement labor travel time lost profit home damages and other contingent liabilities and costs including without limitation costs associated with experts investigations analyses attorneys and other professionals and services The Kraus warranty is a comprehensive and explicit limit of liability and all items outside of it are not addressable by or the responsibility o...

Page 12: ...www kraususa com ...