background image

Page 1

97631C  (REV. D - 06/17)  

Warning

To avoid risk of electrical shock, personal injury or death, disconnect from electrical power supply and shutoff water 

supply before installing this plumbing kit.

Caution

To avoid property damage, personal injury and voiding your warranty:

•  Have this kit installed by an authorized person. (Installation person should be familiar with water cooler plumbing, 

refrigeration systems and general plumbing practices.)

•  Install this kit into one of the Halsey Taylor models listed above.

•  Make sure you read, understand and follow the instructions.

•  Wear hand and arm protection. Use caution when working inside the water cooler.  Edges inside the water cooler 

can be sharp.  

•  Wear eye safety goggles.

Required Tools

To install this kit the following tools are required:

•  Phillips Screwdriver

•  Needle Nose Pliers

•  1/4” and 5/16” Nut or Socket Driver

•  Tubing Cutter (Mini)

•     11/16” (.687”) diameter hole punch or drill bit.

•     Large adjustable wrench.

 Operation of Quick Connect Water Fittings:

Cooler is provided with lead-free connectors which utilize an

“O”-ring water seal. To remove tubing from the fitting, relieve

water pressure, push in on the darker gray collar before

pulling on the tubing. To insert tubing, push tube straight 

into fitting until it reaches a positive stop, approximately 

3/4” (19mm).  Deburr cut tube ends before inserting into the 

Quick Connect Fitting.  Burrs on the tube end will cut the 

internal “O”-Ring and will allow the fitting to leak.

OPERATION OF QUICK CONNECT FITTINGS

TUBE IS 

SECURED

IN POSITION

SIMPLY PUSH IN

TUBE TO ATTACH

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

Parts List

Refer to the illustration to make sure you receive all plumbing kit parts.  If any parts are missing contact your 

Halsey Taylor distributor.  Depending on model, not all parts are required.

7

2

3

4

6

5

PART  NO. 

DESCRIPTION

56092C

15009C

70683C

70682C

70817C

100322740560

75630C

Poly Tubing

Glass Filler Nipple

Connector 1/4" Tubing

Tee 1/4" Tubing 

Elbow 1/4"

Gasket (4)

Glass Filler 

1

2

3

4

5

6

7

ITEM 

NO.

1

NOTE: 

Replacement plumbing hardware components may be ordered as a kit: 1000002033 Glass Filler Hardware 

and Waterway.

Glass Filler Plumbing Kit

Part Number 96852CA

This plumbing kit is designed to be used with Halsey Taylor  

HTVZ, HAC, S-Series, SCWT, SW and WM Models manufactured after December 1998.

Summary of Contents for 96852CA

Page 1: ...move tubing from the fitting relieve water pressure push in on the darker gray collar before pulling on the tubing To insert tubing push tube straight into fitting until it reaches a positive stop app...

Page 2: ...687 diameter hole in the cooler basin per dimensions shown HAC Model Overview The following illustration shows the tube routing before and after the installation of the Glass Filler Kit Before Non Pr...

Page 3: ...ly tube Cut a 6 inch long piece of Item 1 Connect one end of tube to tee Item 4 and other end to water regulator inlet A Cut a 12 inch long piece of Item 1 Connect to tee Item 4 and to Glass Filler Ni...

Page 4: ...d tank and provide a supply line to the glass filler A Note Item numbers in the following steps refer to items in Parts List on page 1 Step 1 2 SCWT Model STEP 1 Remove Cooler Front Panel Remove front...

Page 5: ...filler supply tube Cut a 6 inch long piece of Item 1 Connect one end of tube to tee Item 4 and other end to water regulator inlet A Cut a 12 inch long piece of Item 1 Connect to tee Item 4 and to Glas...

Page 6: ...r Note Item numbers in the following steps refer to items in Parts List on page 1 SW WM Model STEP 1 Remove Cooler Front Panel Remove front panel Remove screws on under side of front panel A Remove fr...

Page 7: ...r tube removed in Step 3 cut length of tube to 10 inches and connect to regulator outlet STEP 3 Cut and Remove Internal Plumbing Remove tank to bubbler tube A Disconnect bubbler tube at chilled tank w...

Page 8: ...basin If basin needs to be removed disconnect tube from bubbler refer to detail on page 1 of operation of quick connect fittings Remove pushbutton regulator assy A by removing chrome cover nut and pu...

Page 9: ...e Item 2 Connect water inlet strainer to the copper tube connected to the chiller inlet This is now the water inlet line Connect bubbler to regulator using a piece of polytube Item 1 STEP 4 Reassemble...

Page 10: ...routing before and after the installation of the Glass Filler Kit The water storage tank must be converted to a pressurized tank for the glass filler to operate properly The tank is non pressurized i...

Page 11: ...check Assemble basin to the unit Reattach with screws removed in Step 2 Turn on water supply and reconnect electrical supply Run water through the bubbler by depressing pushbar and through glass fille...

Page 12: ...6 17 FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1 800 834 4816 2222 CAMDEN COURT OAK BROOK IL 60523 630 574 3500 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1 800 260 6640 2 5 5 6 4 GLASS FILLER...

Reviews: