10
and/or the result of annual checks.
The equipment must be systematically checked if in doubt or after a fall and at least every twelve months by the manufacturer or a competent person* and
in strict compliance with the manufacturer’s periodic examination procedures (and in particular the Inspection Guides ref. GI XX-XXXXXX-XX), in
order to ensure its strength and therefore the safety of the user. The product data sheet should be completed (in writing) after each verification. The date of
inspection and date of the next inspection must be indicated on the data sheet. It is also recommended to put the date of the next inspection on the product.
*: refer to the definition of a competent person on our website under: Info/Technical Advice
MAINTENANCE AND STORAGE:
(These instructions must be strictly observed)
During transportation, keep the equipment away from any cutting edges and keep it in its packaging. Clean with water, wipe with a cloth and hang in
a ventilated room to dry naturally, ensuring that it is away from any direct light or source of heat; the same applies for elements that may have got wet
during use. The system must be stored in its packaging in a cool, dry and ventilated room.
Summary of Contents for FA 60 007 04
Page 41: ...41 NOTES...