38
WP-577VH - Protocol 3000
Command -
LOAD
Command Type - System - Packets
Command Name
Permission
Transparency
Set:
LOAD
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Load file to device
#
LOAD
␠
file_name,size
␍
Get:
-
-
Response
Data sending negotiation:
* Device -
~
01
@
LOAD
␠
file_name,size
␠
READY
␍␊
* End User (+Device)-
Send file in Protocol Packets
* Device -
~
01
@
LOAD
␠
file_name, size
␠
OK
␍␊
Parameters
file_name
- name of file to save on device
size
- size of file data that is sent.
Response Triggers
Notes
Command -
MODEL?
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
-
-
-
Get:
MODEL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device model
#
MODEL?
␍
Response
~nn@
MODEL
␠
model_name
␍␊
Parameters
model_name - String of up to 19 printable ASCII chars
Response Triggers
Notes