40
WP-577VH - Protocol 3000
Command -
PRIO
Command Type - System
Command Name
Permission
Transparency
Set:
PRIO
Administrator
Public
Get
PRIO?
Administrator
Public
Description
Syntax
Set:
Set input priority
#
PRIO
␠
input_id,prio
␍
Get:
Get input priority
#
PRIO?
␠
input_id
␍
Response
~ nn@
PRIO
␠
input_id,prio
␍␊
Parameters
input_id -
window number setting new source
prio -
assigned priority (1.. max priority)
Response Triggers
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if PRIO was set by any other external control device
(button press, device menu and similar)
Notes
The PRIO max value may vary for different devices
Command -
PRIORITY
Command Type - System
Command Name
Permission
Transparency
Set:
PRIORITY
Administrator
Public
Get:
PRIORITY?
Administrator
Public
Description
Syntax
Set:
Set input priority
#
PRIORITY
␠
layer
,
PRIORITY1, PRIORITY2
…
PRIORITYn
␍
Get:
Get input priority
#
PRIORITY?
layer
␍
Response
~ nn@
PRIORITY
␠
layer,PRIORITY1, PRIORITY2… PRIORITYn
␍␊
Parameters
layer
PRIORITY1
- priority of first input
PRIORITYn
- priority of input n
Response Triggers
Notes
WP-577VH
– layer parameter is not used
Summary of Contents for WP-577VH