28
WP-577VH - Protocol 3000
Command -
AV-SW-MODE
Command Type - System
Command Name
Permission
Transparency
Set:
AV-SW-MODE
End user
Public
Get:
AV-SW-MODE?
End user
Public
Description
Syntax
Set:
Set input auto switch mode (per output)
#
AV-SW-MODE
␠
layer,output_id, mode
␍
Get:
Get input auto switch mode (per output)
#
AV-SW-MODE?
␠
layer,output_id
␍
Response
~ nn@
AV-SW-MODE
␠
layer,output_id, mode
␍␊
Parameters
layer
output_id
-
1….num of system outputs
mode
- 0 - manual
1 - priority switch
2 - last connected switch
Response Triggers
Notes
Command -
AV-SW-TIMEOUT
Command Type - System
Command Name
Permission
Transparency
Set:
AV-SW-TIMEOUT
End User
Public
Get:
AV-SW-TIMEOUT?
End User
Public
Description
Syntax
Set:
Set auto switching timeout
#
AV-SW-TIMEOUT
␠
action,time_out
␍
Get:
Get auto switching timeout
#
AV-SW-TIMEOUT?
␠
action
␍
Response
~ nn@
AV-SW-TIMEOUT
␠
action,time_out
␍
Parameters
action
0 - on video signal loss timeout
1 - on new video signal detected switch timeout
timeout
- timeout in seconds
Response Triggers
Notes