background image

 

WP-110xl - Connecting and Installing the WP-110xl

 

 

4.1 

Grounding the Wall Plate 

Grounding the 

WP-110xl

 is recommended. The grounding wire is connected to the 

rear of the chassis of the unit. The grounding screw is used to earth the unit to the 

ground of the building. This helps prevent static electricity from interfering with 

product performance. 

To connect the grounding to the WP-110xl as shown in 

Figure 3

1.  Crimp the ring-tongue terminal to the building grounding point wire.  

(We recommend that you use a green-yellow #18 AWG wire (0.82mm

2

) crimped with a 

proper hand-tool). 

2.  Insert the M3x6 screw through the toothed locking washers and the ring-

tongue terminal in the order shown in 

Figure 3

3.  Insert the M3x6 screw (with the two toothed lock washers and ring-tongue 

terminal in place) into the grounding screw hole on the rear of the 

WP-110xl

 

and tighten the screw. 

 

Figure 3: Ground Connection 

Item 

M3x6 Screw 

M3 Toothed lock washers 

M3 Ring tongue terminal 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for WP-110xl

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL WP 110xl UXGA Data Line Transmitter P N 2900 300294 Rev 3...

Page 2: ......

Page 3: ...onnecting and Installing the WP 110xl 6 4 1 Grounding the Wall Plate 7 4 2 Wiring the TP LINE OUT RJ 45 Connector 8 5 Capturing the EDID 9 5 1 Capturing the EDID from a Display Device 9 5 2 Loading th...

Page 4: ...P 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan C...

Page 5: ...the best performance Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and...

Page 6: ...isted Pair UTP skew free cable Kramer BC XTP may be advantageous and UTP cable might also be preferable for long range applications In any event when using UTP cable it is advisable to ensure that the...

Page 7: ...od and the TP 124 for 100m range The WP 110xl comes in three models the WP 110xl 69mm US version and the two WP 110xl 80 86mm European versions More specifically the WP 110xl features Resolution up t...

Page 8: ...nnector Connects to the computer graphics source 2 ON LED Lights green when powered on 3 12V GND Terminal Block Connects to the 12V DC power supply 4 LINE OUTPUT RJ 45 Connector Connects to the twiste...

Page 9: ...example in Figure 2 1 Connect the LINE OUTPUT RJ 45 connector on the rear panel of the WP 110xl to the TP receiver for example the PT 120 or the TP 126xl 2 Ground the wall plate see Section 4 1 3 Conn...

Page 10: ...110xl as shown in Figure 3 1 Crimp the ring tongue terminal to the building grounding point wire We recommend that you use a green yellow 18 AWG wire 0 82mm2 crimped with a proper hand tool 2 Insert t...

Page 11: ...g the TP LINE OUT RJ 45 Connector This section defines the TP pinout using a straight pin to pin cable with RJ 45 connectors EIA TIA 568B Figure 4 TP PINOUT PIN Wire Color 1 Orange White 2 Orange 3 Gr...

Page 12: ...to the 15 pin HD connector of the display and turn the display on 3 Connect the 12V DC power adapter to the power terminal block see Figure 1 on the WP 110xl and connect the adapter to the mains elec...

Page 13: ...er adapter to the power terminal block see Figure 1 on the WP 110xl and connect the adapter to the mains electricity 4 Press the EDID capture button item 1 on Figure 5 and Figure 6 The EDID status LED...

Page 14: ...WP 110xl Capturing the EDID 11 Figure 6 WP 110xl EU Wall Plate...

Page 15: ...32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing WALL PLATE SIZE 2 gang EU US DIMENSIONS 2 gang USA 11 4cm x 3 5cm x 11 4cm 4 49 x 1 4 x 4 49 W D H 2 gang E...

Page 16: ......

Page 17: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300294 Rev 3 SAFETY...