KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol 3000
26
11
Kramer Protocol 3000
The
VS-88SDI
can be operated using serial commands from a PC, remote
controller, or touch screen. The unit communicates using the default Kramer
Protocol 3000 but can also use Kramer Protocol 2000.
This section describes:
•
How to switch between Protocol 3000 and Protocol 2000 (see
section
11.1
)
•
Kramer Protocol 3000 syntax (see section
11.2
)
•
Kramer Protocol 3000 commands (see section
11.3
)
11.1 Switching Protocols
Protocols can be switched either from the front panel buttons or by
transmitting protocol commands.
To switch protocols using the front panel buttons:
•
To choose Protocol 2000, press LOCK and OUT 2 at the same time
•
To choose the Protocol 3000, press LOCK and OUT 3 at the same
time
To switch protocols using protocol commands:
•
To switch from Protocol 3000 to Protocol 2000, send the following
command:
#P2000<CR>
•
To switch from Protocol 2000 to Protocol 3000, send the following
command:
0x38, 0x80, 0x83, 0x81
Note
: If you are using Kramer’s Windows
®
-based control software
1
it
operates only with Protocol 2000. If the
VS-88SDI
is set to Protocol 3000,
it automatically switches to Protocol 2000.
1 Download the latest software from our Web site at
http://www.kramerelectronics.com