Communication Parameters
22
9
Communication Parameters
The following table lists the communication parameters for Protocol 2000
and Protocol 3000.
Table 7: Communication Parameters
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to Input
1):
0x01, 0x81, 0x81, 0x81
Example (Output 1 to Input
1):
#AV 1>1<CR>
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000<CR>
Front Panel:
Press and hold Output 1 and
Output 2 simultaneously
Front Panel:
Press and hold Output 1 and Output 3
simultaneously
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39
Power cycle the unit while holding in the Factory Reset
button, located on the rear panel of the unit.
TCP Port #: 5000
UDP Port #: 50000
10 Using the P3K Wizard
P3K is a Kramer software program for accessing and changing device
parameters and upgrading the machine firmware. The P3K program can be
downloaded from the Kramer Web site at
www.kramerelectronics.com
.
10.1 Changing the Device Parameters
To change the device parameters do the following:
1. Connect a PC to the
VS-88SDI
using any one of the following connections:
•
Connect a serial cable from an RS-232 9-pin D-sub rear panel
port on the PC to the
VS-88SDI
as explained in section
6.1
.
•
Connect an RJ-45 Ethernet cable from the Ethernet port on the
PC to the Ethernet port on the
VS-88SDI
.