Kramer Electronics Ltd.
VS-88DT
– Kramer Protocol
55
SIG-TYPE
Command Name
Permission
Transparency
Set:
SIG-TYPE
End User
Public
Get
SIG-TYPE?
End User
Public
Description
Syntax
Set:
Set signal type on input/output
#
SIG-TYPE
␠
stage, stage_id,type
␍
Get:
Get signal type on input/output
#
SIG-TYPE?
␠
stage,stage_id
␍
Response
~nn@
SIG-TYPE
␠
stage,stage_id,type
␍␊
Parameters
stage
–
input/output (0
– Input, 1 – Output)
stage_id
– number of chosen stage (1.. max number of inputs/outputs)
type
–
signal type (0
–
No signal, 1
–
DVI, 2
–
HDMI, 3
–
DisplayPort, 4
–
HDBaseT, 5
–
SDI, 6
–
VGA,
7
–
Follow output, 8
–
DGKat)
Response Triggers
After execution, response is sent to the com port from which the Set/Get
was received
After execution, response is sent to all com ports if SIG-TYPE
was set by any other external control
device (button press, device menu and similar)
Notes
“Set” command is not available for all devices (refer to device specifications)