Kramer Electronics Ltd.
VS-88DT
– Operating the VS-88DT
15
Resetting the Device to Factory Default Configuration
The
VS-88DT
can be reset to factory default configuration either by sending a Protocol 3000
command or by using the front panel buttons.
To reset the device to the factory default configuration by sending a P3000 command:
1. Connect from a PC to the
VS-88DT
via the serial port using the following parameters:
▪
115200, 8, 1, none
2. Send the P3000 command to reset the device to factory default (see
Section Kramer Protocol 3000 Commands
After a few seconds the
VS-88DT
is reset to factory default.
To reset the device to the factory default configuration using the front panel buttons:
1. Press the Menu button.
The Menu button lights and the first option on the menu appears.
2.
Use the up (▲) and down (▼) arrows on the keypad to scroll to the RESET TO
DEFAULT option.
3. Press the Enter button.
The Reset to Default No and Yes options appear.
4.
Use the left (◄) and right (►) arrows on the keypad to select Yes.
5. Press Enter.
After a few seconds the standby readout is displayed and the device is reset to factory
default.
Locking and Unlocking the Front Panel
You can lock the front panel buttons to prevent unwanted key presses from changing the
current configuration.
To lock the front panel:
•
Press and hold the Lock button.
The button lights, the Locked message is displayed briefly, and the front panel buttons
are locked. Pressing any button causes the Locked message to display briefly and the
Lock button to flash
To unlock the front panel:
•
Press and hold the Lock button.
The button no longer lights and the front panel buttons are unlocked