Configuring the Number of Installed Input and Output Ports
27
27
Are you Absolutely sure !!!
Once more TAKE to confirm
6. Press TAKE.
The following is displayed:
Matrix erased!!!
Please, wait …
The matrix is erased. After a few seconds the next option on the Config Menu
is displayed.
8.2.8 Config Menu—Display Firmware Versions
This option displays the main and front firmware versions.
To display the firmware versions:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
Main Firmware Version:
1.0
Front Firmware Version:
1.0
3. Either:
Press BREAKAWAY to exit the Config Menu
Wait approximately 15 seconds for the operation to time out
9 Configuring the Number of Installed Input and Output Ports
When installing or removing a module, you need to set the number of input and
output ports.
To set the number of input/output ports:
1. Press ESC, ENT and LOCK together.
The following is displayed:
Configuration Device
2. Press ENT.
The following is displayed:
Test Board: 0 MaxInput:32 MaxOutput:32
Note:
The number of input and output ports can only be set in units of four, for
example, 4 x 4, 24 x 24 or 32 x 32.
3. Using the numeric keys, enter the number of input and output ports installed.
The TAKE button flashes.
4. Press TAKE.
The number of installed ports is saved and the display reverts to the
output/input display.