DC Modular

EN

Installa on details

NL

Installa edetails

Smart terminal design allows dual mirrored cable lug connec ons.

5 wire interface cable for external control by panel switch, ba ery monitor or BMS. Compa ble with 
two wire or single wire On/Off control. Includes status wire for controlling indicator light or providing 
feedback to BMS.

Special fiber reinforced plas c housing offers excellent high temperature proper es, good chemical 
resistance and high strength.

Robust transparent covers with breakouts to allow wire access from any direc on.

Local Open and Close bu ons on top, to manually override the switch state.

Stainless steel studs, washers and nuts for op mal corrosion resistance.

Smart high current magne c latching relay, draws virtually no current in On (Close) or Off (Open) 
state.

Silver alloy contacts and silver plated copper busbars, for maximum conduc vity and high reliability 
when switching live loads.

Unique grid op mized footprint allows space saving arrangements with other DC Modular products.

General opera on | 

Algemene werking

RBS features

Precau ons

Please install this product in a dry indoor loca on, as close as possible to the ba ery. To be installed 
only by qualified technicians.

To avoid fire hazards, use correctly sized cables which are suitable to carry the expected load currents 
in your applica on. The maximum con nuous RBS current ra ng of 500A is only valid when a total 
cable size of at least 200mm² is connected to the M10 studs. Or when the RBS is part of a DC Modular 
system containing large busbars and fuseholders.

To avoid fire hazards or damaging the RBS, please make sure that all nuts are securely  ghtened. 
Please apply our recommended torque ra ng of 22Nm for the M10 nuts.

To avoid fire hazards or damaging the RBS, please make sure that spring- and flat washers are always 
placed directly below the nut. Never place washers between: busbar and cable lug, mul ple cable lugs 
on the same stud, busbar and linkplate or cable lug and linkplate.

Please make sure that all connec on cables are properly strain relieved, to avoid excessive mechanical 
stress on the RBS.

Voorzorgsmaatregelen

Installeer dit product alleen in een droge omgeving, zo dicht mogelijk bij de accu. Installa e enkel te 
verrichten door een gekwalificeerd installateur.

 

Gebruik om brandgevaar te voorkomen alleen correct gedimensioneerde kabels, geschikt voor de te 
verwachten stromen. De maximale RBS stroom van 500A, is alleen geldig wanneer de kabels op de 
M10 terminals een kwadratuur van minimaal 200mm² hebben. Of wanneer de RBS onderdeel is van 
een DC Modular systeem, er grote busbars en/of zekeringhouders mee in verbinding staan.

Om brandgevaar te voorkomen, dient u er voor te zorgen dat alle moeren voldoende worden 
aangedraaid. Raadpleeg hiervoor ons aanbevolen aandraaimoment van 22Nm voor de M10 moeren.

Om schade aan de RBS of brandgevaar te voorkomen, dienen de veerring en de vlakke ring zich al jd 
direct onder de moer te bevinden. Plaats ringen nooit tussen: busbar en krimpoog, meerdere 
krimpogen op dezelfde bout, busbar en verbindingsplaat of krimpoog en verbindingsplaat.

Zorg voor voldoende trekontlas ng op alle kabels. Dit om een te hoge mechanische belas ng op de 
RBS te voorkomen.

Contacten van een zilver legering en verzilverde koperen aansluitplaten zorgen voor de beste geleiding 
en een hoge betrouwbaarheid bij het schakelen van belas ngen.

Slim bistabiel relais voor het schakelen van hoge stromen, verbruikt zelf vrijwel geen stroom in de ‘aan’ 
(gesloten) of ‘uit’ (geopende) stand.

Lokale ‘Open’ en ‘Close’ knoppen kunnen de controle van het hoofdcontact overnemen.

5-draads aansluitkabel voor externe besturing vanuit een paneel schakelaar, ba erij monitor of BMS. 
Geschikt voor 2-draads en enkeldraads besturing van het hoofdcontact. Inclusief status draad voor 
sturing van indicator of terugkoppeling naar BMS.

Op male corrosiebestendigheid door gebruik van RVS bouten, ringen en moeren.

Unieke raster gebaseerde basisafme ngen staan zeer compacte forma es van meerdere DC Modular 
producten toe.

Speciale vezel versterkte kunststof behuizing biedt uitstekende hoge temperatuur eigenschappen, 
goede bestendigheid tegen chemische stoffen en een zeer hoge sterkte.

Transparante afdekkappen met uitbreekbare kanten voor kabelverbindingen vanuit meerdere hoeken.

Door een slim aansluitklem ontwerp kunnen twee krimpogen ook gespiegeld worden gemonteerd.

RBS eigenschappen

500A Remote Ba ery Switch (RBS)
500A Extern gestuurde accuschakelaar (RBS)

EN

NL

1

2

3

4

5

1

2

3

4

5

!

!

TBS Electronics BV | De Marowijne 3 | 1689AR Zwaag | The Netherlands | www.tbs-electronics.com

TBS RBS Manual Rev3endf

RBS specifica ons

Parameter

DCM-RBS-12-500

(art# 5074510)

(art# 5074520)

DCM-RBS-24-500

Contact circuit (electrical)

Rated voltage

60Vdc

Nominal current @ 25°C

500A (see Precau on #2)

Cranking current (1 minute)

1000A

Nominal make / break current

500A (0 .. 34Vdc)

350A (35 .. 60Vdc)

Peak make / break current

1600A (0 .. 34Vdc)

1200A (35 .. 60Vdc)

Control circuit (electrical)

Coil / supply voltage (+Vdc)

7 .. 17Vdc

14 .. 34Vdc

Coil / supply current (idle state)

< 100

μ

A

Coil / supply current (state change)

< 4A

< 3A

General

Remote control ¹⁾

By control wires (length 40cm, max. 15m)

Local control

On/Standby, Close contact, Open contact

Indicators

Contact open, Contact close, Error and Setup

Protected against

High temperature, High/Low supply voltage, 

Igni on (ISO 8846)

Mechanical life

100000 cycles

Electrical life

10000 cycles (@ 400A/24V/resis ve)

Opera ng temperature range

-20 .. +60°C

Connec on studs / DCM grid size

M10 / 1 x 3

Protec on class / weight

IP 65 / 800 grams

Standards

EMC: 2014/30/EU, Low voltage direc ve: 2014/35/EU,

RoHS: 2011/65/EU, Automo ve: EN 50498, ISO 8846

0

I

OPEN

CLOSE

(2 sec)

Open contact

Open contact

Close contact

Sluit contact

Power bu on. Press 2 seconds to turn the RBS
on or off. When turned off, the RBS will 
automa cally open the contact. In off mode, the 
RBS will ignore any control wire commands. 

Aan/uit knop. Druk 2 seconden om de RBS in- of
uit te schakelen. Wanneer deze wordt uitgeschakeld,
zal het contact automa sch geopend worden. In de
uit stand zullen alle stuurkabel commando’s 
genegeerd worden.

Green flash - contact open
Red flash - error mode

Groen knipperend - contact open
Rood knipperend - foutmodus

Green flash - contact closed
Red flash - error mode

Groen knipperend - contact gesloten
Rood knipperend - foutmodus

Change control mode | 

Wijzig stuurmodus

When in off mode, press all three bu ons simultaneously for three seconds to enter the setup mode:

Vanuit de uit-stand alle drie knoppen tegelijk ingedrukt houden voor drie seconden om de setup 
modus te ac veren:

RBS specifica es

Parameter

(art# 5074510)

DCM-RBS-12-500

(art# 5074520)

DCM-RBS-24-500

Contact circuit (elektrisch)

Maximale spanning

60Vdc

Max. con nustroom @ 25°C

500A (zie voorzorgsmaatregel #2)

Aanloopstroom (1 minuut)

1000A

Nominale maak- / verbreekstroom

350A (35 .. 60Vdc)

500A (0 .. 34Vdc)

Piek maak- / verbreekstroom

1600A (0 .. 34Vdc)

1200A (35 .. 60Vdc)

Besturingscircuit (elektrisch)

Spoel / voedingsspanning (+Vdc)

7 .. 17Vdc

14 .. 34Vdc

Spoel / voedingsstroom (rust)

< 100

μ

A

Spoel / voedingsstroom (schakelen)

< 4A

< 3A

Algemeen

Bediening op afstand ¹⁾

Via besturingsbedrading (lengte 40cm, max. 15m)

Bediening lokaal

Aan/Standby, Sluit contact, Open contact

Indicatoren

Contact open, Contact gesloten, Fout en Instelmodus

Beveiligd tegen

Hoge temperatuur, Hoge/lage voedingsspanning, 

ontsteking (ISO 8846)

Mechanische levensduur

100000 cycli

Elektrische levensduur

10000 cycli (@ 400A/24V/resis ve)

Werkingstemperatuur (omgeving)

-20 .. +60°C

Verbindingsbouten / rastermaat

M10 / 1 x 3

Beschermingsklasse / Gewicht

IP 65 / 800 gram

Normen

EMC: 2014/30/EU, Low voltage direc ve: 2014/35/EU,

RoHS: 2011/65/EU, Automo ve: EN 50498, ISO 8846

50.0mm

150.0mm

64.5mm

94.0mm

38.0mm

138.0mm

Dimensions | 

Afme ngen

Nut | 

Moer

Spring washer | 

Veerring

Washer | 

Ring

Cable lugs | 

Krimpogen

Assembly sequence:

Assemblage volgorde:

0

I

O

P

E

N

C

L

O

S

E

(2 sec)

Battery |

 Accu

Ground

Massa

Fuseholder

Zekeringhouder

Busbar

Busbar

5A - 8A fuse

5

- 8A zekering

1A fuse

1A zekering

R

ed | 

R

ood

Black | 

Zwart

Close

Sluiten

Open

Openen

Br

own | 

Bruin

Or

ang

e | 

Oranje

External momentary switch

(TBS art.no. 5095000-1)

Externe momentschakelaar

(TBS art.nr. 5095000-1)

Yellow | 

Geel

R

Wire | 

Draad

Standard func on | 

Standaard func e

Red | 

Rood

+Vdc con nuous supply |

 +Vdc con nue voeding

Black | 

Zwart

Ground | 

Massa

Brown | 

Bruin

+Vdc pulse closes contact | 

+Vdc puls sluit contact

Orange | 

Oranje

+Vdc pulse opens contact | 

+Vdc puls opent contact

Yellow | 

Geel

 ¹⁾

Status (LED) output | 

Status (LED) uitgang

 ¹⁾

¹⁾ The Status output is a ground referenced open collector port with a 
   maximum switching capacity of 34V / 100mA (Rout ≈ 10

 

Ω

)

¹⁾ De Status uitgang is een aan massa gerefereerde open collector poort met
   een maximale schakelcapaciteit van 34V / 100mA (Ruit ≈ 10

 

Ω

)

Wiring example |

 Bedradingsvoorbeeld 

Error table (both LEDs flashing red)

Fou abel (beide LEDs knipperen rood)

Cause | 

Oorzaak

Remedy | 

Remedie

Supply voltage too low

Voedingsspanning te laag

Increase supply voltage

Verhoog voedingsspanning

Supply voltage too high

Voedingsspanning te hoog

Decrease supply voltage

Verlaag voedingsspanning

RBS Temperature too high

RBS temperatuur te hoog

Reduce the contact current, check all

cable connec ons

controleer alle kabelverbindingen

Reduceer de stroom door het contact, 

Contacts are welded

Contacten zijn verkleefd

Vervang de RBS

Replace the RBS

Error table |

 Fou abel

R = 5mm (x4)

¹⁾ Panel switch with LED indicator op onally available (Art. no. 5095000-1)

¹⁾ Paneelschakelaar met LED indicator op oneel beschikbaar (Art. nr. 5095000-1)

8

7

3

1

2

0

OPEN

I

CLOSE

+

+

(3 sec)

Control mode table | 

Stuurmodus tabel

Modus nr.

Mode no.

Open LED

Open LED

Close LED

Close LED

Control mode

Control modus

1

2-draads, geen contact wijziging bij opstarten

2-wire, no contact change at power-up

2

2-draads, contact sluit bij opstarten

2-wire, contact closes at power-up

3

2-wire, contact opens at power-up

2-draads, contact opent bij opstarten

4

single-wire, normally open contact

enkeldraads, normaal geopend contact

5

single-wire, normally closed contact

enkeldraads, normaal geloten contact

G

O

G

G

O

O

O

O

G

=

=

=

LED off

LED uit

LED green

LED groen

LED orange

LED oranje

Step through the control modes by pressing the OPEN (up) or CLOSE (down) bu ons

Stap door de controlmodus op es m.b.v. de OPEN (omhoog) of CLOSE (omlaag) knoppen

+Vdc pulse on brown wire to close, +Vdc pulse on orange wire to open.

+Vdc puls op bruine draad voor sluiten, +Vdc puls op oranje draad voor openen.

Modes 1, 2 & 3:

When the desired control mode is selected, press the Power bu on for 2 seconds to save the se ng.
Press the Power bu on again for 2 seconds to ac vate the RBS with the new control mode.

Wanneer de gewenste controlmodus geselecteerd is, druk op de aan/uit knop voor 2 seconden om de
instelling op te slaan. Druk wederom 2 seconden op de aan/uit knop om de RBS te ac veren met de
nieuwe controlmodus.

+Vdc con nuous on brown wire to close, 0Vdc on brown wire to open. Orange wire
not used.

+Vdc con nu op bruine draad voor sluiten, 0Vdc op bruine draad voor openen. 
Oranje draad niet gebruikt.

Mode 4:

+Vdc con nuous on brown wire to open, 0Vdc on brown wire to close. Orange wire
not used.

+Vdc con nu op bruine draad voor openen, 0Vdc op bruine draad voor sluiten. 
Oranje draad niet gebruikt.

Mode 5:

Main cable installa on | 

Hoofdkabel installa e

Reviews: