KRAMER: SIMPLE CREATIVE TECHNOLOGY
VP-747 Communication Protocol
50
Control Type
Function Param1
Param2
Param3
Param4
Description
Set
Get
0
1
208
-100 ~ 100
-
-
-
Program Yellow
Saturation
0
1
209
0: Custom 1
1: Custom 2
2: Custom 3
3: Custom 4
-
-
-
Program Custom
Input Target
0
1
210
512~3071
-
-
-
Program Input
Setting User
Mode HT
0
1
211
32~(HS-48)
-
-
-
Program Input
Setting User
Mode HW
0
1
212
80~(HT-HA-12)
-
-
-
Program Input
Setting User
Mode HS
0
1
213
640~1920
<= (HT-92)
-
-
-
Program Input
Setting User
Mode HA
0
1
214
0: -
1: +
-
-
-
Program Input
Setting User
Mode HP
0
1
215
384~2047
-
-
-
Program Input
Setting User
Mode VT
0
1
216
2~(HS-13)
-
-
-
Program Input
Setting User
Mode VW
0
1
217
15~(VT-VA-1)
-
-
-
Program Input
Setting User
Mode VS
0
1
218
480~1200
<= (VT-16)
-
-
-
Program Input
Setting User
Mode VA
0
1
219
0: -
1: +
-
-
-
Program Input
Setting User
Mode VP
0
1
220
25 ~ 165 (Integer
Value)
0 ~ 999
(Decimal Value)
-
-
Program Input
Setting User
Mode OCLK
0
1
221
0: Off
1: On
-
-
-
Program Input
Setting Enable
0
-
222
-
-
-
-
Program Input
Setting User
Mode Save
0
1
223
0: Custom 1
1: Custom 2
2: Custom 3
3: Custom 4
Program Custom
Output Target
0
1
224
512~3071
-
-
-
Program Output
Setting User
Mode HT
0
1
225
32~(HS-48)
-
-
-
Program Output
Setting User
Mode HW
0
1
226
80~(HT-HA-12)
-
-
-
Program Output
Setting User
Mode HS
0
1
227
640~1920
<= (HT-92)
-
-
-
Program Output
Setting User
Mode HA
0
1
228
0: -
1: +
-
-
-
Program Output
Setting User
Mode HP