VP-747 Communication Protocol
45
45
Control Type
Function Param1
Param2
Param3
Param4
Description
Set
Get
0
1
91
32 ~ (HS-48)
-
-
-
Preview Input
Setting User
Mode HW
0
1
92
80~(HT-HA-12)
-
-
-
Preview Input
Setting User
Mode HS
0
1
93
640~1920
<= (HT-92)
-
-
-
Preview Input
Setting User
Mode HA
0
1
94
0: -
1: +
-
-
-
Preview Input
Setting User
Mode HP
0
1
95
384~2047
-
-
-
Preview Input
Setting User
Mode VT
0
1
96
2~(HS-13)
-
-
-
Preview Input
Setting User
Mode VW
0
1
97
15~(VT-VA-1)
-
-
-
Preview Input
Setting User
Mode VS
0
1
98
480~1200
<= (VT-16)
-
-
-
Preview Input
Setting User
Mode VA
0
1
99
0: -
1: +
-
-
-
Preview Input
Setting User
Mode VP
0
1
100
25 ~ 165 (Integer
Value)
0 ~ 999
(Decimal Value)
-
-
Preview Input
Setting User
Mode OCLK
0
1
101
0:Off
1:On
-
-
-
Preview Input
Setting Enable
0
-
102
-
-
-
-
Preview Input
Setting User
Mode Save
0
1
103
0: Custom 1
1: Custom 2
2: Custom 3
3: Custom 4
-
-
-
Preview Custom
Output Target
0
1
104
512 ~ 3071
-
-
-
Preview Output
Setting User
Mode HT
0
1
105
32 ~ (HS-48)
-
-
-
Preview Output
Setting User
Mode HW
0
1
106
80~(HT-HA-12)
-
-
-
Preview Output
Setting User
Mode HS
0
1
107
640 ~ 1920
-
-
-
Preview Output
Setting User
Mode HA
0
1
108
0: -
1: +
-
-
-
Preview Output
Setting User
Mode HP
0
1
109
384~2047
-
-
-
Preview Output
Setting User
Mode VT
0
1
110
2~(HS-13)
-
-
-
Preview Output
Setting User
Mode VW
0
1
111
15~(VT-VA-1)
-
-
-
Preview Output
Setting User