KRAMER: SIMPLE CREATIVE TECHNOLOGY
Operating the VP-471 3G HD-SDI to DVI Scaler
6
To connect the VP-471, as illustrated in the example in
Figure 3
:
1. Connect the digital SDI camera to the SDI IN BNC connector.
2. Connect the SDI OUT BNC connector to the SDI display.
3. Connect the S/PDIF AUDIO OUT RCA connector to the digital AV receiver.
4. Connect the LEFT and RIGHT AUDIO OUT RCA connectors to the
unbalanced stereo audio amplifier.
5. Connect the DVI OUT connector to the DVI projector.
6. Connect the 5V DC power adapter to 5V DC power socket and to the mains
electricity (not shown in the illustration).
6
Operating the VP-471 3G HD-SDI to DVI Scaler
The
VP-471
is operated directly via the front panel buttons and via the OSD menu
(see
Section
6.2
).
6.1 Using the Front Panel Buttons
During normal operation (without the OSD), the front panel buttons perform in the
following manner:
•
MENU
: Displays the OSD Main Menu (see
Section 6.2
). Press a second
time to close the OSD
•
FREEZE
: Freezes the display. Press a second time to unfreeze the display
•
MENU
and
AUTO ADJUST
: Press together to set the output to 720p
(1280x720)
•
ENTER
and
FREEZE
: Press together to set the output to XGA (1024x768)
6.2 Using the OSD
The OSD is used to set a variety of parameters.
When using the OSD, the front panel buttons operate in the following manner:
•
MENU
: Opens the OSD main menu (see
Table 3
). Press a second time to
close the OSD
•
ENTER
: Selects the highlighted menu item or parameter
•
–
: Steps up through the menu list or decrements the parameter value
•
+
: Steps down through the menu list or increments the parameter value
Note:
After a period of 15 sec with no button activity, the OSD menu times-out
automatically.
Example of Setting a Parameter
To set the green offset value of the display output to 42:
1. From normal operation, press MENU.
The OSD main menu appears on the screen.