Default Parameters
27
11 Default Parameters
11.1 Default Communication Parameters
Table 7
lists the default communication parameters as used in Kramer Electronics
products.
Table 7: Default Communication Parameters
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to Input 1):
0x01, 0x81, 0x81, 0x81 Example (Output 1 to Input 1):
#AV 1>1<CR>
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000<CR>
Front Panel:
Press and hold Output 1 and Output 3
simultaneously
Front Panel:
Press and hold Output 1 and
Output 2 simultaneously
Ethernet
To reset the IP settings to the factory reset values, power cycle the device while holding in the Fact Reset button,
located on the rear panel of the unit
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
TCP Port #:
5000
UDP Port #:
50000
Maximum UDP Ports:
10
Maximum TCP Ports:
4
11.2 Default Audio and Video Parameters
Table 8
lists the default audio and video parameters as used in Kramer Electronics
products.
Table 8: Default Audio and Video Parameters
Parameter
Default
Audio-follow-video
On
Input audio gain
0dB
Output audio gain
0dB
Switched input
1